JULIUS 14 4 ERP

EN

Instruction and

 

recommendation booklet

*1.038493ENG*

Содержание JULIUS 11 4 ERP

Страница 1: ...JULIUS 11 4 ERP JULIUS 14 4 ERP EN Instruction and recommendation booklet 1 038493ENG ...

Страница 2: ......

Страница 3: ...in compliance with the regulations in force according to the manufacturer s instructions and by an authorised company which has specific technical expertise in the system sector as required by Law Improper installation or assembly of the Immergas appliance and or components accessories kit and devices can cause unexpected problems to people animals and objects Read the instructions provided with t...

Страница 4: ...ription of the anomalies 10 2 7 Switching off the water heater 10 2 8 Replacing the batteries 10 2 9 Emptying the water heater 10 2 10 Protection against freezing 10 2 11 Case cleaning 10 2 12 Decommissioning 10 3 Checks and maintenance 11 3 1 Hydraulic diagram 11 3 2 Wiring diagram 12 3 3 Troubleshooting 12 3 4 Converting the water heater to other types of gas 12 3 5 Possible adjustments 12 3 6 Y...

Страница 5: ...r incorrect operation turn the appliance off and contact an authorised company e g the Authorised Tech nical Assistance centre which has specifically trained staff and original spare parts Do not attempt to modify or repair the appliance alone Failuretocomplywiththeaboveimpliespersonal responsibility and invalidates the warranty Installation regulations Julius water heaters cannot be installed in ...

Страница 6: ...the water heater Water connec tions must be made in a rational way following the set up of the water heater couplings on the Attention to preserve the duration and the ef ficiency features of the appliance in the presence of water whose features can lead to the deposit of scale installation of the polyphosphate dispenser kit is recommended 1 5 ELECTRIC POWER SUPPLY This water heater is powered by ...

Страница 7: ...e case of repeated interventions of the fumes exhaust control device check the fumes exhaust flue and the ventilation of the room in which the water heater is located 1 9 GAS SYSTEM START UP To start up the system refer to the technical standard in force This divides the systems and therefore the start up operations into three categories new systems modified systems re activated systems In particu...

Страница 8: ... 4 Ignition electrode 5 Ignition and flame control P C B 6 battery compartment 7 Connection pipe pressure point 8 Chimney safety thermostat 9 Overheating safety thermostat 10 Valve burner pipe pressure point 11 Gas selector 12 Temperature selector switch 13 DHW heat exchanger 14 Combustion chamber 15 Burner 16 Water gas valve ...

Страница 9: ...at can put the room into de pression at the same time as the water heater un less there are additional openings dimensioned in a way to satisfy the further necessity for air For the dimensioning of these additional open ings refer to qualified technical staff and to current technical Attention using any components that use electrical power requires some fundamental rules to be observed never pull ...

Страница 10: ...r to the hydraulic connections To replace the bat teries open the relevant compartment by pulling the lid down and removing the batteries present Insert the new batteries respecting the polarities indicated on the internal wall of the lid itself N B only use new LR20 1 5V alkaline batter ies Dispose of the batteries replaced according to the indications supplied by the manufacturer Do not use re c...

Страница 11: ...1 Overheating safety thermostat 2 Valve burner pipe pressure point 3 Valve intake diaphragm 4 Connection pipe pressure point 5 Chimney safety thermostat 6 Fumes hood 7 DHW heat exchanger 8 Pilot group 9 Burner 10 Water gas valve AC Domestic hot water outlet AF Domestic cold water inlet G Gas supply ...

Страница 12: ... CONVERTING THE WATER HEATER TO OTHER TYPES OF GAS If the appliance has to be converted to a differ ent gas type to that specified on the data plate request the relative conversion kit for quick and easy conversion The gas conversion operation must be carried out by an authorised company e g Authorised Technical After Sales Service 3 5 POSSIBLE ADJUSTMENTS Regulation of the water heater heat outpu...

Страница 13: ...casing can be completely removed as follows 1 Loosen the lower screws a that fix the lower protection grid b and the casing c 2 Release the casing c from the lower brackets d pulling the sides slightly outwards 3 Pull the casing towards you in the lower side 4 Push the casing upwards in a way to be able to extract it from the upper hooks e ...

Страница 14: ...89 3 8 5 7310 1 04 1 80 18 4 0 78 5 60 57 1 0 76 7 04 71 8 7 8 6708 0 95 1 40 14 3 0 71 4 70 47 9 0 70 5 90 60 2 METHANE G20 BUTANE G30 PROPANE G31 THERMAL POWER THERMAL POWER BURNER GAS FLOW RATE PRESS BURNER NOZZLES BURNER GAS FLOW RATE PRESS BURNER NOZZLES BURNER GAS FLOW RATE PRESS BURNER NOZZLES kW kcal h m3 h mbar mm H2 O kg h mbar mm H2 O kg h mbar mm H2 O 24 4 20984 2 89 11 30 115 2 2 15 2...

Страница 15: ...at Q Nom Min mg kWh 205 135 270 149 235 142 Flue temperature at nominal output C 183 189 184 Flue temperature at minimum output C 126 130 126 Julius 14 4 ErP Gas nozzle diameter mm 1 35 0 80 0 80 supply pressure mbar mm H2 O 20 204 29 296 37 377 Pilot nozzle diameter mm 0 26 0 22 0 22 Gas cone seats mm 9 0 9 0 9 0 Gas cone inlet code 0855 0881 0881 Gas cone outlet code 0863 0884 0884 Gas inlet val...

Страница 16: ... temperature of 15 C The data relevant to domestic hot water per formance refer to a dynamic inlet pressure of 2 bar and an inlet temperature of 15 C the values are measured directly at the water heater outlet considering that to obtain the data declared mixing with cold water is necessary The max sound level emitted during water heater operation is 55 dBA The sound level value is referred to semi...

Страница 17: ...uel consumption for the domestic hot water function AFC 7 GJ Water heating energy efficiency ηwh 66 Parameter value Annual fuel consumption for the domestic hot water function AFC 12 GJ Water heating energy efficiency ηwh 76 For proper installation of the appliance refer to chapter 1 of this booklet for the installer and current installation regulations For proper maintenancerefertochapter3ofthisb...

Страница 18: ...lect the actual energy efficiency after installation since such efficiency is affected by additional factors such as the heat loss in the distribution system and the size of the products compared to the size and features of the building Facsimile for filling in domestic hot water production system package fiche 3 13 PARAMETERS FOR FILLING IN THE PACKAGE FICHE Should you wish to install an assembly...

Страница 19: ...4 35 36 36 37 38 40 39 50 55 60 65 75 80 85 100 115 123 131 130 150 160 170 163 188 200 213 M L XL XXL 3 2 3 2 The energy efficiency of the set of products indicated in this sheet may not reflect the actual energy efficiency after installation since such efficiency is affected by additional factors such as the heat loss in the distribution system and the size of the products compared to the size a...

Страница 20: ...immergas com Immergas S p A 42041 Brescello RE Italy Tel 0522 689011 Fax 0522 680617 Certified company ISO 9001 This instruction booklet is made of ecological paper Cod 1 038493ENG rev ST 002036 000 09 15 Inglese per IRLANDA IE ...

Отзывы: