2
Room temperature hook-up only in standard mode
3
Room temperature hook-up in standard and in reduced mode enabled
Access
&
"
System settings
"
&
"
Program
"
&
"
Heating circuit
"
&
"
Heating circuit 1/2
"
&
"Room T activation "
(
l
/
m
)
Standard setting
0
Setting range
0 to 3
Start optimisation
Operating instructions
Vitocal 300
Maximum flow temperature correction
Prerequisites: Room temperature
sensor installed and enabled (see
page 105).
Setting the maximum value, by which
the flow temperature can be modified
through the room temperature hook-
up.
A
Flow temperature
B
Differential between set room
temperature and outside tempera-
ture
C
Heating curve
D
Feasible positive correction range
(0.1 to 10.0 K)
E
Feasible negative correction
range (0.1 to 10.0 K)
Room temperature hook-up
(cont.)
106
Heating circuit control settings
55
92
901
GB