Access
&
"
System settings
"
&
"
Program
"
&
"
Heating circuit
"
&
"
Heating circuit 1/2
"
&
"min. flow temp."
(
1
/
!
)
Standard setting
10 °C
Setting range
1 to 30 °C
DHW during party mode
This setting determines whether,
when party mode has been enabled
(see operating instructions
Vitocal 300), the DHW cylinder should
be heated up first (setting "
Yes
") or
whether the system should immedi-
ately switch over to heating mode
(setting "
No
").
Access
&
"
System settings
"
&
"
Program
"
&
"
Heating circuit
"
&
"
Heating circuit 1/2
"
&
"Hot water with Party"
("
YES
"/"
NO
")
Standard setting
YES
Setting range
YES/NO
Excess reaction
Coordination of the heat drawn off in
the secondary circuit when the heat
pump produces an excess of heat or
the heat drawn by the secondary cir-
cuit is suddenly choked off.
Settings:
0
No heat drawn off
1
Heat will be drawn off only in case of a critical excess, i.e. if critical tem-
peratures were reached in the heat pump circuit or the minimum heat
pump runtime has not yet been reached
2
Heat will be drawn off, even if the excess heat being created is not critical
for the heat pump
Access
&
"
System settings
"
&
"
Program
"
&
"
Heating circuit
"
Minimum flow temperature
(cont.)
104
Heating circuit control settings
55
92
901
GB
Содержание VITOCAL 300
Страница 19: ...Connection diagram Open CLOSE System version 1 cont 19 Preparing for installation 5592 901 GB...
Страница 22: ...Connection diagram Open CLOSE System version 2 cont 22 Preparing for installation 5592 901 GB...
Страница 66: ...Main menu Information A See page 67 Menu structure overview Information 66 Control unit settings 5592 901 GB...
Страница 137: ...Control PCB 137 Connection and wiring diagrams 5592 901 GB Service...
Страница 140: ...Parts lists cont 140 Parts lists 5592 901 GB...
Страница 141: ...Parts lists cont 141 Parts lists 5592 901 GB Service...
Страница 159: ...159 5592 901 GB...