8
C
DHW circulation
D
Opening for 230 V cables
E
Cold water
F
Liquid line
G
Hot gas line
H
Heating water flow
K
Heating water return
L
Solar circuit return
M
Solar circuit flow
Connection sizes for hydraulic connections
Pos.
Sym-
bol
Meaning
Connection
B
–
DHW
Rp ¾
C
–
DHW circulation
G 1
E
–
Cold water
Rp ¾
F
Refrigerant lines from/to
the external unit:
■ Liquid line
7
connection pipe:
(supplied pipe bends)
10 mm
UNF thread:
⅝
For type AWT-AC 241.A04, a reduction
from 10 to 6 mm is necessary down-
stream of the pipe bend (reducer ⅝ to
⁷
⁄
₁₆
supplied).
G
■ Hot gas line
7
connection pipe:
(supplied pipe bends)
16 mm
UNF thread:
⅞
For type AWT-AC 241.A04, a reduction
from 16 to 10 mm is necessary down-
stream of the pipe bend (reducer ⅞ to
¾ supplied).
H
Heating water flow
Cu 28 x 1 mm
K
Heating water return
Cu 28 x 1 mm
L
–
Solar circuit return
DN 20 pipe sleeve for multi connect sys-
tem
M
–
Solar circuit flow
1.
Prepare the connections on the heat-
ing water and the DHW side.
Flush the heating system.
2.
Prepare the electrical connections.
Preparing for installation
Requirements regarding on-site connections
(cont.)
5623 661 GB
Содержание Vitocal 242-S
Страница 26: ...26 6 8 P301 P501 P303 P302 X25 F23 F6 7 Installation sequence Installing the internal unit cont 5623 661 GB ...
Страница 27: ...27 SLP N 9 11 aCH sG lJ 10 Installation sequence Installing the internal unit cont 5623 661 GB Installation ...
Страница 28: ...28 X20 2x 16 17 2x 12 14 18 13 15 Installation sequence Installing the internal unit cont 5623 661 GB ...
Страница 29: ...29 2x 4x 4x 6x 21 19 20 22 Installation sequence Installing the internal unit cont 5623 661 GB Installation ...
Страница 32: ...32 Installation sequence Installing the internal unit cont 5623 661 GB ...
Страница 95: ...95 Removing cover from programming unit if necessary 5 4 4x Troubleshooting Repairs cont 5623 661 GB Service ...
Страница 110: ...110 0003 0006 0005 0008 0007 0001 0009 0010 0002 0004 Parts lists internal unit Internal unit casing cont 5623 661 GB ...