46
Connections on the M2IO electronics module of the cylinder module
The mains connection and PlusBus wiring chamber of
accessories takes place on the M2IO electronics mod-
ule of the cylinder module.
TS1
TS2
5A
5B
P2
28
P1
21
40A
40
TS4 17
74
74
Fig. 40
TS1
%
A Cylinder temperature sensor top (connected
in the delivered condition)
TS2
%
B Cylinder temperature sensor bottom (con-
nected in the delivered condition)
TS4
aJ
Return temperature sensor (connected in
the delivered condition)
P1
sA
Cylinder loading pump (connected in the
delivered condition)
P2
sK
DHW circulation pump
fÖ
Power supply via gas condensing module
fÖ
A
Power supply for further accessories
jF
PlusBus connection, further accessories
Installation sequence
Electrical connections
(cont.)
5853335