143
A
B
C
Fig. 96
1.
Shut off and drain the boiler on the heating water
and DHW sides. See page 137.
2.
Undo 2 screws
A
. Pull plate heat exchanger
B
to
the side and remove from the top.
3.
Check the connections on the heating water and
DHW sides for contamination and scaling; replace
the plate heat exchanger if necessary.
4.
Install in reverse order using new gaskets.
Removing the flow sensor
1.
1.
2.
3.
Fig. 97
Troubleshooting
Repairs
(cont.)
5853335
Diagnosis