Recommended power cables for all
types:
■ Heat pump control unit (230 V~):
3 x 1.5 mm
2
(5 x 1.5 mm
2
with power-
OFF)
■ Compressor (400 V~):
5 x 2.5 mm
2
Max. lead length:
50 m
■ Instantaneous heating water heater
(400 V~, if installed):
5 x 2.5 mm
2
Max. lead length:
50 m
Overview of possible system schemes
The following table provides an overview
of
all
possible system schemes.
Selected system schemes are explained
using system examples (see from
page 42).
Components
System scheme (parameter 7000)
0
1
2
3
4
5
6
7
8
9
10
11
Heating circuit
A1
–
X
X
–
–
X
X
–
–
X
X
–
M2
–
–
–
X
X
X
X
X
X
X
X
–
M3
–
–
–
–
–
–
–
X
X
X
X
–
DHW cylinder
X
–
X
–
X
–
X
–
X
—
X
–
Heating water buffer cylinder
–
0
0
X
X
X
X
X
X
X
X
–
External heat source
0
0
*1
0
*1
0
0
0
0
0
0
0
0
–
Instantaneous heating water heater
0
0
0
0
0
0
0
0
0
0
0
–
Swimming pool
–
0
0
0
0
0
0
0
0
0
0
–
Solar thermal system
(with integral solar control module of the Vitotronic or with the Vitosolic 200)
0
–
0
–
0
–
0
–
0
–
0
–
Cooling
A1
–
0
0
–
–
0
0
–
–
0
0
–
M2
–
–
–
0
0
0
0
0
0
0
0
–
M3
–
–
–
–
–
–
–
0
0
0
0
–
Sep. cooling circuit
0
0
0
0
0
0
0
0
0
0
0
–
*1
Only in conjunction with a heating water buffer cylinder.
Preparing for installation
Installation
(cont.)
5600 161 GB
Содержание BW 01.A06
Страница 65: ...65 Removing the top panel 1 Installation sequence Siting the heat pump cont 5600 161 GB Installation ...
Страница 121: ...121 Opening the shield Troubleshooting Repairs cont 5600 161 GB Service ...
Страница 122: ...122 Overview of internal components M C D F E B G O N K P A J I L Troubleshooting Repairs cont 5600 161 GB ...
Страница 166: ...166 5600 161 GB ...
Страница 167: ...167 5600 161 GB ...