76
Plug
sYA
Terminals
Function
Explanation
211.4
M
r
M
■ 3-way diverter valve for
heating/DHW
■ Circulation pump for cylin-
der heating
■ Cylinder primary pump
■ 2-way shut-off valve
Connection values
■ Output: 130 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Connect on site.
In type BWC, the circulation pump for
cylinder heating is connected at the fac-
tory.
211.5
NC/AC
Cooling control
NC function (natural cool-
ing)
Circuit on site
Connection values
■ Output: 10 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Plug
sYS
Terminals
Function
Explanation
212.1
AC
AC
Cooling control
AC function (active cooling)
Circuit on site
Connection values
■ Output: 10 W
■ Voltage: 230 V~
■ Max. switching current: 4(2) A
Installation sequence
Electrical connections
(cont.)
5600 161 GB