131
DHW
Parameter
Code
Delivered condi-
tion
Commis-
sioning
"Set DHW temperature"
6000
500 (
≙
50 °C)
"Min. DHW temperature"
6005
100 (
≙
10 °C)
"Max. DHW temperature"
6006
600 (
≙
60 °C)
"Hysteresis DHW temperature heat
pump"
6007
50 (
≙
5 K)
"Hysteresis DHW temperature booster
heater"
6008
100 (
≙
10 K)
"Start optimisation for DHW heating"
6009
0
"Stop optimisation for DHW heating"
600 A 0
"Set DHW temperature 2"
600C
600 (
≙
60 °C)
"Temperature sensor at bottom of
DHW cylinder"
600E
0
"Enable booster heaters for DHW heat-
ing"
6014
0
"Enable electric heaters for DHW heat-
ing"
6015
1
"Priority DHW heating with combi cyl-
inder"
6016
0
"Start attempts for DHW after high
pressure shutdown"
6017
1
"Operating mode cylinder primary
pump"
6020
Do not adjust
Electric booster heater
Parameter
Code
Delivered condi-
tion
Commis-
sioning
"Enable instantaneous heating water
heater"
7900
1
"Enable instant. heating water heater
for central heating"
7902
1
"Max. output instantaneous heating
water heater"
7907
3
"Output for instant. heating water
heater at power-OFF"
790A
0
"Dual mode temp instant. heating wa-
ter heater"
790B
500 (
≙
50 °C)
Commissioning/service reports
Control parameters report
(cont.)
5782 201 GB
Service
Содержание AWT-AC 221.A04
Страница 18: ...18 10 9 11 Installation sequence Installing the internal unit cont 5782 201 GB ...
Страница 20: ...20 2x 4x 6x 4x 22 21 20 19 Installation sequence Installing the internal unit cont 5782 201 GB ...
Страница 88: ...88 Removing cover from programming unit if necessary 5 4 4x Troubleshooting Repairs cont 5782 201 GB ...
Страница 102: ...102 0006 0003 0005 0001 0007 0008 0002 0004 0010 0009 Parts lists internal unit Internal unit casing cont 5782 201 GB ...
Страница 155: ...155 5782 201 GB ...