34
F
E
D
C
Safety assembly supplied
C
Pressure gauge
D
Connection G¾
E
Quick-action air vent valve
F
Safety valve
1.
Connect the secondary lines to the
heat pump:
!
Please note
Ensure hydraulic connections
are tight.
Ensure the diaphragm grom-
mets of the pipe outlets are
seated correctly (if necessary,
seal with sealing tape). (See
chapter "Assembly and seal-
ing faces to note").
2.
Install the supplied safety assembly:
Either to the on-site line in the heating
water return
or
to the secondary circuit connection
set (accessory)
Connection set installation
instructions
3.
Fill and vent the secondary circuit.
4.
Thermally insulate pipes inside the
building.
Note
■ For underfloor heating circuits, install
a temperature limiter to restrict the
maximum temperature in the under-
floor heating system (see chapter
"Connecting a temperature limiter as a
maximum temperature limiter in
underfloor heating systems").
■ Ensure the minimum flow rate, e.g.
with overflow valve (see chapter
"Specification").
■ The secondary circuit must be equip-
ped on site with an expansion vessel.
Installation sequence
Connecting the secondary circuit
(cont.)
5782 201 GB
Содержание AWT-AC 221.A04
Страница 18: ...18 10 9 11 Installation sequence Installing the internal unit cont 5782 201 GB ...
Страница 20: ...20 2x 4x 6x 4x 22 21 20 19 Installation sequence Installing the internal unit cont 5782 201 GB ...
Страница 88: ...88 Removing cover from programming unit if necessary 5 4 4x Troubleshooting Repairs cont 5782 201 GB ...
Страница 102: ...102 0006 0003 0005 0001 0007 0008 0002 0004 0010 0009 Parts lists internal unit Internal unit casing cont 5782 201 GB ...
Страница 155: ...155 5782 201 GB ...