101
External Controls
43 VIDEO STANDARD SELECT
Function
The external control equipment sets the VIDEO STANDARD of the plasma monitor.
Transmission Data
DFH
80H
60H
5CH
01H
DATA00 CKS
DATA00: 01H: 3.58NTSC
02H: 4.43NTSC
03H: PAL
04H: SECAM
05H: AUTO1
0BH: PAL60
0CH: AUTO2
0DH: PAL-M
0EH: PAL-N
ACK
7FH
60H
80H
5CH
01H
DATA00 CKS
DATA00: 01H: 3.58NTSC
02H: 4.43NTSC
03H: PAL
04H: SECAM
05H: AUTO1
0BH: PAL60
0CH: AUTO2
0DH: PAL-M
0EH: PAL-N
44 FREQUENCY REQUEST
Function
The external control equipment inquires the Horizontal frequency, Vertical frequency,
Horizontal sync polarity, Vertical sync polarity, Mode, and Resolution of the plasma
monitor.
Transmission Data
1FH
80H
60H
26H
00H
CKS
ACK
7FH
60H
80H
26H
0BH
DATA00 to DATA10
CKS
Horizontal frequency
DATA00: Integer part
00H: 0 (No signal: 00H)
|
FFH: 256
DATA01: One decimal place
00H: 0 (No signal: 00H)
|
09H: 9
Vertical frequency
DATA02: Integer part
00H: 0 (No signal: 00H)
|
FFH: 256
DATA03: One decimal place
00H: 0 (No signal: 00H)
|
09H: 9
Horizontal sync polarity
DATA04: 00H: -
01H: Positive
02H: Negative
Содержание PlasmaView VP-42
Страница 1: ...VP 42 VP 42HD VP 50 VP 60 Owner s Manual...
Страница 114: ...113 DIMENSIONS 40 301 1 665 24 220 4 899 1 474 42 diagonal VP 42 VP 42HD...
Страница 115: ...114 Dimensions 2 172 48 407 29 286 1 667 3 941 50 diagonal VP 50...
Страница 116: ...115 Dimensions 2 227 58 117 34 912 4 855 1 903 60 diagonal VP 60...
Страница 117: ...RUMA 010550 4 04 v2 0 VIDIKRON 2900 Faber Street Union City CA 94587 Ph 510 324 5900 Fax 510 324 5905 1 888 4 VIDIKRON...