98
External Controls
37 FACTORY
Function
The external control equipment resets the user adjustment of the plasma monitor.
Transmission Data
1FH
80H
60H
54H
00H
CKS
ACK
3FH
60H
80H
54H
00H
CKS
38 AUDIO SELECT SET
Function
The external control equipment sets combinations of audio and video inputs for the
plasma monitor.
Transmission Data
DFH
80H
60H
70H
02H
DATA00 DATA01 CKS
DATA00: AUDIO
01H: AUDIO 1
02H: AUDIO 2
03H: AUDIO 3
DATA01: VISUAL INPUT
01H: Video 1
02H: Video 2
03H: Video 3
05H: HD
(HD1 or DVD or DVD1)
06H: HD2 (DTV2)
07H: RGB 1/PC1
08H: RGB 2/PC2
0CH: RGB 3/PC3
ACK
The plasma monitor returns the following ACK when the input is switched
.
3FH
60H
80H
70H
00H
CKS
* The plasma monitor returns “Not Available” when selecting the video input same as the
one set at one of the AUDIO 1 to 3.
Example:
The plasma monitor returns “Not Available” when selecting the VIDEO1 for AUDIO2 or
VIDEO3 after VIDEO1 has been set to AUDIO1.