For best results with VideoRay CoPilot RI, the compass calibration should be completed to optimize its performance in your location.
If you have moved 1 degree of Latitude or more from your last operating location or if you are operating near a large ferrous object
like a ship, you should calibrate the compass. The compass calibration can be found in VideoRay Cockpit.
The remainder of this page is an expert from the Pro 4 Operator's Manual. For more information and context, see the
Pro 4 Operator's
Manual
.
Compass Calibration Vector Nav
To calibrate the Vector Nav compass, follow these steps:
1. Start VideoRay Cockpit.
2. Click on the Engine Room button on the Control Bar.
3. Unlock the controls.
4. Click on the Calibrate Compass button, which has the magnet icon on it.
5. In the window that opens, select a Virtual Port (recommended Port is COM17). Set the baud rate to 115200 if it is not already.
6. Minimize the Engine Room
7. Start the Vector Nav Sensor Explorer from the Windows Start Menu.
8. Select a Virtual Port (recommended port is COM18). Set the baud rate to 115200 if it is not already.
9. Ensure Query Sensor after connecting is checked.
10. Click on "Connect."
11. Right click on Sensor A in the upper left pane, and select Tasks>Perform Hard/Soft Iron Calibration.
12. In the window that opens, click on Start Calibration.