9. Appliance installation.
Trained and competent technicians or companies must perform the installing a pellet stove! Qualified technicians
should perform all activities in inspection and repair of electrical components. Switch off the pellet stove from the
electric supply before any inspection or repair!
Refer to the regulations valid for the country, where the pellet stove will be used, if you do not find the information you are
interested in this instruction manual.
It is not recommended to install a pellet stove in rooms where there is mounted another heater. If it does, it must be equipped
with a separate air duct.
Compatibility with other devices:
Pellet stove should not be installed in the same room in which there are absorbers and / or devices that reduce ventilation in the
room.
Checking electrical connections:
Pellet stove is equipped with a power cable to be connected to a voltage 230V / 50Hz. Changes exceeding by 10% the voltage can
damage the appliance. Electrical grid-circuit must comply with the provisions of the laws and requirements for grounding.
According to the requirements for electrical grid-circuit connection, pellet stove should be installed so as to ensure free access to
the plug and socket (230V / 50Hz). According to the safety requirements it’s prohibited the room where the pellet stove is installed
to have electrical installation mounted on the floor. Lack of bonding / grounding can cause damage for which the manufacturer is
not responsible.
Positioning:
To ensure well operation, pellet stove should be leveled. The floor on which is placed the pellet stove must be of non-combustible
materials (concrete, marble, terracotta, etc.)
Given the easy servicing and refueling, we recommend the following minimum free distance around the pellet stove: 1000 mm at
the front, back and sides -500 mm, top -minimum 1000 mm.
Safe distances for fire safety:
When installing a pellet stove and storage of wood pellets must be respected the fire requirements!
It is recommended that an appropriate place to mount a fire extinguisher be ensured.
It is forbidden to store the wood pellets directly to the pellet stove or a distance of less than 400 mm.
The optimal distance between the pellet stove and combustible materials is 800mmin front and 300 mm from the sides and the
back. Inflammable objects should not be placed on the top board of the pellet stove.
If the chimney is connected to the timber wall or other inflammable material, suitable materials such as ceramic wool should be
used to isolate it.
Fresh air opening:
Imperative to ensure submission of fresh air!
The room, in which is mounted pellet stove must have an opening for fresh air with a cross section of not less than 80 cm² in order
to ensure a sufficient supply of oxygen necessary for combustion. Additionally, it can be delivered outside air through a steel pipe
of Ø 50 mm. In this case, it is possible to emerge condensate. If necessary, the opening for external air can be protected by a grid
whose light-section should not be less than 12 cm². Pipe for outside air has to be mounted on the nearest outer wall to the pellet
stove. Its length should not exceed 1 m, should not have curves and its location has to prevent clogging. The outer end of the pipe
must end with a knee 90˚, downward or be provided with protection against wind.
Chimneys:
Pellet stove works constantly with a fume extractor and pressure in the flue pipes and chimney.
It is forbidden flue gases to be discharged directly from the pellet stove through the wall into the atmosphere. Required installed
chimney, which takes flue gases safe for human health altitude over the area of habitation.
Only the pellet stove should use chimney and no other appliances have to be connected to it. The flue gases are emitted from the
combustion chamber of the pellet stove to the atmosphere through a flue socket Ø 80 mm located in the rear. It is recommended
at the beginning of the vertical section of the chimney to mount a T-fitting, with a section for collecting condensate. Pellet stove
must be connected to the chimney by steel flue pipes, certified according to EN 1856. The flue pipe system must be hermetically
insulated with materials resistant to high temperatures (heat-resistant silicone or grease). Allowed to have a horizontal section
with a length of 2 m. Horizontal section must be a minimum slope of 3% and not more than two curves at 90°.
If the flue socket of the pellet stove is connected to a metal chimney, it must have a vertical portion length of not less than 1.5 m
and fitted with a wind protection. Chimney may be located internally or externally. It should be well insulated.
If the pellet stove is connected to a masonry chimney, it must be intended for appliances for solid fuel. If the chimney has a size
larger from Ø150 mm in diameter, internally along its entire length must be installed tube of stainless steel with a diameter of
Ø150 mm, as the free space has to be isolated by masonry. All parts of the chimney should have free access to inspection. At the
Содержание VITTORIA 10
Страница 1: ...INSTRUCTION MANUAL for installation and operation of air pellet stove VITTORIA 8 VITTORIA 10...
Страница 4: ...Victoria 05 Ltd 4 3 Technical data and dimensions Drawing 1...
Страница 19: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 19...
Страница 20: ...Victoria 05 Ltd 20...
Страница 21: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 21...
Страница 22: ...Victoria 05 Ltd 22...
Страница 23: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 23...
Страница 27: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 27...