Technical data and nominal performance:
Technical data
:
Performance parameters:
Vittoria 8
Vittoria 10
Nominal heat output
6.1 kW
8.0 kW
Reduced heat output
3.0 kW
3.7 kW
Maximum operating temperature
260
°
С
260
°
С
Distance to adjacent combustible materials
side
= 300 mm
rear
= 300 mm
in front
= 800 mm
Efficiency
87.76 %
85.87 %
СО emissions [13% О
2
]
at nominal heat output
at reduced heat output
0.0166 %
0.0281 %
0.0156 %
0.0291 %
Flue gases temperature
at nominal heat output
at reduced heat output
125
°
С
78
°
С
181
°
С
88
°
С
Flue gases mass
at nominal heat output
at reduced heat output
5.81 gr/s
2.96 gr/s
6.28 gr/s
2.98 gr/s
Draught
at nominal heat output
at reduced heat output
11 Ра
11 Pa
11.5 Ра
10.5 Pa
Duration of combustion
at nominal heat output
at reduced heat output
15h
34h
11h
28h
Fuel consumption minimum / maximum
0.7/1.525kg/h
0.867/2.067 kg/h
Type and dimensions of fuel
Wood pellets, Ø 6 mm/length 25 mm
Pellet fuel hopper capacity
24 kg
24 kg
Flue socket diameter
Ø 80 mm
Ø 80 mm
Heating volume
≈ 120m
3
≈ 155 m
3
Net weight
103 kg
103 kg
The dimensions of the heated room are calculated based on pellets with calorific value not less than 4300 ccal/kg and heat loss of
heated room 33 ccal/m³h.Consideration must be given to the availability of external devices that can influence the operation of
the pellet stove.
All activities for repairing of electrical components, maintenance and / or inspections should be performed by qualified
personnel. Unplug the appliance from the main electrical supply before you start these activities.
Electrical data:
Performance parameters:
Power supply
230 Vac (+/-10%), 50 Hz
Switch on / off
Yes
Average power consumption
130 W
Average power consumption during ignition
430 W
Main power protection
Fuse 4А, 250 VAC5 х 20
We reserve the right to make changes in products without prior notice, in order to improve their performance.
4. Safety devices.
Fume thermocouple: It is placed at the exit of the flue socket to measure the temperature of the flue gases. Controls ignition and
at very high temperature (260
0
C) triggers lock phase. Alarm (High Temp).
Vacuum gauge: It is placed at the exit of the flue socket. Account values of draught into the combustion chamber and compared
with the pressure in the room.
Temperature sensor of the pellet fuel hopper: Placed on the auger housing near the pellet fuel hopper. It interrupts feeding of the
pellets, if its temperature reaches 75°С.
Fuse: At the main switch of the pellet stove there is built in fuse.
Содержание VITTORIA 10
Страница 1: ...INSTRUCTION MANUAL for installation and operation of air pellet stove VITTORIA 8 VITTORIA 10...
Страница 4: ...Victoria 05 Ltd 4 3 Technical data and dimensions Drawing 1...
Страница 19: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 19...
Страница 20: ...Victoria 05 Ltd 20...
Страница 21: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 21...
Страница 22: ...Victoria 05 Ltd 22...
Страница 23: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 23...
Страница 27: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 27...