5

 

 

Technical data and nominal performance: 

Technical data

Performance parameters: 

Vittoria 8 

Vittoria 10 

Nominal heat output 

6.1 kW 

8.0 kW 

Reduced heat output 

3.0 kW 

3.7 kW 

Maximum operating temperature 

260

°

С 

260

°

С 

Distance to adjacent combustible materials 

side 

= 300 mm 

rear 

= 300 mm 

in front 

= 800 mm 

Efficiency 

87.76 % 

85.87 % 

СО emissions [13% О

2

at nominal heat output 
at reduced heat output 

 

0.0166 % 
0.0281 % 

 

0.0156 % 
0.0291 % 

Flue gases temperature  

at nominal heat output 
at reduced heat output 

 

125

°

С 

78

°

С 

 

181

°

С 

88

°

С 

Flue gases mass 

at nominal heat output 
at reduced heat output 

 

5.81 gr/s 
2.96 gr/s 

 

6.28 gr/s 
2.98 gr/s 

Draught 

at nominal heat output 
at reduced heat output 

 

11 Ра 
11 Pa 

 

11.5 Ра 
10.5 Pa 

Duration of combustion 

at nominal heat output 
at reduced heat output 

 

15h 
34h 

 

11h 
28h 

Fuel consumption minimum / maximum 

0.7/1.525kg/h 

0.867/2.067 kg/h 

Type and dimensions of fuel 

Wood pellets, Ø 6 mm/length 25 mm 

Pellet fuel hopper capacity 

24 kg 

24 kg 

Flue socket diameter 

Ø 80 mm 

Ø 80 mm 

Heating volume 

≈ 120m

≈ 155 m

Net weight 

103 kg 

103 kg 

The dimensions of the heated room are calculated based on pellets with calorific value not less than 4300 ccal/kg and heat loss of 
heated room 33 ccal/m³h.Consideration must be given to the availability of external devices that can influence the operation of 
the pellet stove. 

All activities for repairing of electrical components, maintenance and / or inspections should be performed by qualified 
personnel. Unplug the appliance from the main electrical supply before you start these activities. 

 

Electrical data: 

Performance parameters: 

Power supply 

230 Vac (+/-10%), 50 Hz 

Switch on / off 

Yes 

Average power consumption 

130 W 

Average power consumption during ignition 

430 W 

Main power protection 

Fuse 4А, 250 VAC5 х 20 

We reserve the right to make changes in products without prior notice, in order to improve their performance. 

 

4. Safety devices. 

Fume thermocouple: It is placed at the exit of the flue socket to measure the temperature of the flue gases. Controls ignition and 
at very high temperature (260

0

C) triggers lock phase. Alarm (High Temp). 

Vacuum gauge: It is placed at the exit of the flue socket. Account values of draught into the combustion chamber and compared 
with the pressure in the room. 

Temperature sensor of the pellet fuel hopper: Placed on the auger housing near the pellet fuel hopper. It interrupts feeding of the 
pellets, if its temperature reaches 75°С. 

Fuse: At the main switch of the pellet stove there is built in fuse. 

Содержание VITTORIA 10

Страница 1: ...INSTRUCTION MANUAL for installation and operation of air pellet stove VITTORIA 8 VITTORIA 10...

Страница 2: ...E CONTROL UNIT 10 10 2 3 MAIN MENU 11 10 2 4 INSTALLER SETTINGS 12 10 2 5 SERVICE TECHNICIAN SETTINGS 13 10 3 COLD TEST 14 11 INSTRUCTION MANUAL 14 11 1 WOOD PELLETS LOADING 14 11 2 WOOD PELLET REFUEL...

Страница 3: ...of failure of any of its components Safety components are activated without outside interference Necessary for the proper operating of the pellet stove is its proper installation in accordance with t...

Страница 4: ...Victoria 05 Ltd 4 3 Technical data and dimensions Drawing 1...

Страница 5: ...pellets with calorific value not less than 4300 ccal kg and heat loss of heated room 33 ccal m h Consideration must be given to the availability of external devices that can influence the operation o...

Страница 6: ...outlet and intakes combustion air by vacuum Gear motor Driven auger screw by means of which the pellets are conveyed from the pellet fuel hopper to the combustion chamber Room air fan Ensures additio...

Страница 7: ...from Picture 2 Through the control panel the user can visualize and manage all stages of the operation of the pellet stove 8 Fuel Pellet stove e designed and programmed to burn wood pellets They have...

Страница 8: ...o the timber wall or other inflammable material suitable materials such as ceramic wool should be used to isolate it Fresh air opening Imperative to ensure submission of fresh air The room in which is...

Страница 9: ...after installation to make a detailed instruction of the user Pellet stove is coated by high temperature resistant paint but not against corrosion In case of accumulation of dust surfaces can be clean...

Страница 10: ...appear after the process has been finished If for more than 6 seconds there is no connection to the Control Unit the value will not be saved Day time and night time temperatures To change the require...

Страница 11: ...h Intermediate clean indicates the time left before the system starts cleaning mode Recommended value 600 Pellets indicates the volume of the pellets used during operation mode Input value is gr min D...

Страница 12: ...have to be touched to unlock the display 10 2 4 Installer settings Types of settings for Installer entered with installer password Factory settings Vittoria 8 Vittoria 10 Duration 700 sec 700 sec Fan...

Страница 13: ...s how often the cleaning procedure has to be triggered The set value is summed up from the feed screw working time By this way it s possible to set the cleaning based on the calculation of the amount...

Страница 14: ...me runs out the mode is changed to feeding loading In this mode again a time counter is shown The default time is 70 sec The smoke fan is reducing the power The screw is activated and starts loading i...

Страница 15: ...ny scales that clog the holes Picture 6 Vacuum clean the combustion chamber and all contact edges Clean the glass when it is cold If necessary use appropriate detergent Never vacuum hot coals because...

Страница 16: ...as stopped working Error messages are described below Do not unplug the pellet stove from the main electrical supply during shutdown process In case of failure To restart the pellet stove is necessary...

Страница 17: ...pipes and combustion chamber are clean Flue outlet pipes are clean 15 Frequently Asked Questions The following answers are tentative For more details use the instruction manual What is need to prepare...

Страница 18: ...f the pellet stove has not worked for a long time Can you use other types of fuel than wood pellets NO Pellet stove is designed to work with wood pellets with a diameter of 6 mm The use of another typ...

Страница 19: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 19...

Страница 20: ...Victoria 05 Ltd 20...

Страница 21: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 21...

Страница 22: ...Victoria 05 Ltd 22...

Страница 23: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 23...

Страница 24: ...ass sealing set 11 Combustion chamber set 12 Fire grate 13 Deflector top 14 Handle 15 Fire door set 16 Ashtray 17 Grill for hopper 18 Left side plate set 19 Right side plate set 20 Special tool 21 Dis...

Страница 25: ...the remaining population For other countries please contact you dealer Any warranty repair of the pellet stove is recorded in the diary of warranty Warranty of the pellet stove is NOT VALID in the fol...

Страница 26: ...Victoria 05 Ltd 26 DIARY for repairs under warranty Company Receipt date Type of repair Delivery date Carried out...

Страница 27: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 27...

Страница 28: ...Victoria 05 Ltd 1B Ivan Momchilov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 fax 359 618 60200 e mail info v05 bg http www v05 bg...

Отзывы: