12.2018
INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 / VITTORIA 10
7
The initial ignition of the pellets is carried out by hot air, which is sucked in around the ignition (K) in the combustion chamber
through the fume extractor (G). Fume extractor provides combustion air by sucking in from air inlet Ø40 mm (D) by the room or
by outside atmosphere. Upon submission of air from the room must have provided an influx of outside air.
The flue gases are sucked from the combustion chamber through the fume extractor (G) and are conducted to flue socket Ø 80
mm (F).
Picture.2.
The ash from the combustion process is conducted in an ashtray (O)underneath the combustion chamber. The ashtray must be
periodically cleaned by pouring in a metal container or by a vacuum cleaner, but only when the pellet stove is cold.
By the internal mounted air fan (E), the hot air is pushed in the room and multiplies the efficiency of the pellet stove. The room
temperature is measured by temperature sensor installed in the stove.
High efficiency and low emission of the pellet stove is guaranteed by an electronic control system that manages the amount of
fuel, the flue gases conduction, supplying of combustion air and operation of the air fan. The control panel of the control system
is placed in back of the upper panel of the pellet stove (M) from Picture 2. Through the control panel, the user can visualize and
manage all stages of the operation of the pellet stove.
8. Fuel.
Pellet stove e designed and programmed to burn wood pellets. They have a cylindrical shape and they are made of compressed
by a high-pressure timber, without adhesive and additive materials. The wood pellets are sold in packages weighing 15 kg, which
facilitates their storage. For better combustion, the wood pellets must be stored in dry and ventilated area. Pellet stove is designed,
developed, programmed and tested to operate with wood pellets class A1, according to EN plus and BDS EN ISO 17225-2: 2014
with the following parameters:
Maximum diameter:
Ø 6 mm
Maximum length:
25 mm
Maximum moisture content:
8 %
Maximum ash content:
0.5%
Minimum calorific value:
4300 ccal/kg
Good quality wood pellets ensure good combustion and lower emissions into the atmosphere.
The use of wood pellets with a lower quality results in a need for more frequent cleaning of the combustion chamber, reducing
heat output and efficiency. They are increasing the fuel consumption sensitively. Inadequate wood pellets can cause blockage of
the auger and to stop the operation of the pellet stove.
IF PELLET STOVE IS BLOCKED, THE REASON WILL APPEAR ON THE DISPLAY AND IT WILL BE SAVED.
Using wood pellets of poor quality or non-manufacturer recommended as above may compromise the operation of the
pellet stove and lead to termination of the warranty.
Pellet stove should not be used to burn other types of fuels or materials. Invalid guarantee!
Содержание VITTORIA 10
Страница 1: ...INSTRUCTION MANUAL for installation and operation of air pellet stove VITTORIA 8 VITTORIA 10...
Страница 4: ...Victoria 05 Ltd 4 3 Technical data and dimensions Drawing 1...
Страница 19: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 19...
Страница 20: ...Victoria 05 Ltd 20...
Страница 21: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 21...
Страница 22: ...Victoria 05 Ltd 22...
Страница 23: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 23...
Страница 27: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 27...