background image

12.2018

 

 

 

INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 / VITTORIA 10

 

 

 

7

 

 

The initial ignition of the pellets is carried out by hot air, which is sucked in around the ignition (K) in the combustion chamber 
through the fume extractor (G). Fume extractor provides combustion air by sucking in from air inlet Ø40 mm (D) by the room or 
by outside atmosphere. Upon submission of air from the room must have provided an influx of outside air. 

The flue gases are sucked from the combustion chamber through the fume extractor (G) and are conducted to flue socket Ø 80 
mm (F). 

 

 

Picture.2. 

The ash from the combustion process is conducted in an ashtray (O)underneath the combustion chamber. The ashtray must be 
periodically cleaned by pouring in a metal container or by a vacuum cleaner, but only when the pellet stove is cold. 

By the internal mounted air fan (E), the hot air is pushed in the room and multiplies the efficiency of the pellet stove. The room 
temperature is measured by temperature sensor installed in the stove. 

High efficiency and low emission of the pellet stove is guaranteed by an electronic control system that manages the amount of 
fuel, the flue gases conduction, supplying of combustion air and operation of the air fan. The control panel of the control system 
is placed in back of the upper panel of the pellet stove (M) from Picture 2. Through the control panel, the user can visualize and 
manage all stages of the operation of the pellet stove. 

 

8. Fuel. 

Pellet stove e designed and programmed to burn wood pellets. They have a cylindrical shape and they are made of compressed 
by a high-pressure timber, without adhesive and additive materials. The wood pellets are sold in packages weighing 15 kg, which 
facilitates their storage. For better combustion, the wood pellets must be stored in dry and ventilated area. Pellet stove is designed, 
developed, programmed and tested to operate with wood pellets class A1, according to EN plus and BDS EN ISO 17225-2: 2014 
with the following parameters: 

Maximum diameter:  

Ø 6 mm 

Maximum length:  

25 mm 

Maximum moisture content:  

8 % 

Maximum ash content:  

0.5% 

Minimum calorific value:  

4300 ccal/kg 

Good quality wood pellets ensure good combustion and lower emissions into the atmosphere. 

The use of wood pellets with a lower quality results in a need for more frequent cleaning of the combustion chamber, reducing 
heat output and efficiency. They are increasing the fuel consumption sensitively. Inadequate wood pellets can cause blockage of 
the auger and to stop the operation of the pellet stove. 

IF PELLET STOVE IS BLOCKED, THE REASON WILL APPEAR ON THE DISPLAY AND IT WILL BE SAVED. 

Using wood pellets of poor quality or non-manufacturer recommended as above may compromise the operation of the 
pellet stove and lead to termination of the warranty. 
Pellet stove should not be used to burn other types of fuels or materials. Invalid guarantee! 

Содержание VITTORIA 10

Страница 1: ...INSTRUCTION MANUAL for installation and operation of air pellet stove VITTORIA 8 VITTORIA 10...

Страница 2: ...E CONTROL UNIT 10 10 2 3 MAIN MENU 11 10 2 4 INSTALLER SETTINGS 12 10 2 5 SERVICE TECHNICIAN SETTINGS 13 10 3 COLD TEST 14 11 INSTRUCTION MANUAL 14 11 1 WOOD PELLETS LOADING 14 11 2 WOOD PELLET REFUEL...

Страница 3: ...of failure of any of its components Safety components are activated without outside interference Necessary for the proper operating of the pellet stove is its proper installation in accordance with t...

Страница 4: ...Victoria 05 Ltd 4 3 Technical data and dimensions Drawing 1...

Страница 5: ...pellets with calorific value not less than 4300 ccal kg and heat loss of heated room 33 ccal m h Consideration must be given to the availability of external devices that can influence the operation o...

Страница 6: ...outlet and intakes combustion air by vacuum Gear motor Driven auger screw by means of which the pellets are conveyed from the pellet fuel hopper to the combustion chamber Room air fan Ensures additio...

Страница 7: ...from Picture 2 Through the control panel the user can visualize and manage all stages of the operation of the pellet stove 8 Fuel Pellet stove e designed and programmed to burn wood pellets They have...

Страница 8: ...o the timber wall or other inflammable material suitable materials such as ceramic wool should be used to isolate it Fresh air opening Imperative to ensure submission of fresh air The room in which is...

Страница 9: ...after installation to make a detailed instruction of the user Pellet stove is coated by high temperature resistant paint but not against corrosion In case of accumulation of dust surfaces can be clean...

Страница 10: ...appear after the process has been finished If for more than 6 seconds there is no connection to the Control Unit the value will not be saved Day time and night time temperatures To change the require...

Страница 11: ...h Intermediate clean indicates the time left before the system starts cleaning mode Recommended value 600 Pellets indicates the volume of the pellets used during operation mode Input value is gr min D...

Страница 12: ...have to be touched to unlock the display 10 2 4 Installer settings Types of settings for Installer entered with installer password Factory settings Vittoria 8 Vittoria 10 Duration 700 sec 700 sec Fan...

Страница 13: ...s how often the cleaning procedure has to be triggered The set value is summed up from the feed screw working time By this way it s possible to set the cleaning based on the calculation of the amount...

Страница 14: ...me runs out the mode is changed to feeding loading In this mode again a time counter is shown The default time is 70 sec The smoke fan is reducing the power The screw is activated and starts loading i...

Страница 15: ...ny scales that clog the holes Picture 6 Vacuum clean the combustion chamber and all contact edges Clean the glass when it is cold If necessary use appropriate detergent Never vacuum hot coals because...

Страница 16: ...as stopped working Error messages are described below Do not unplug the pellet stove from the main electrical supply during shutdown process In case of failure To restart the pellet stove is necessary...

Страница 17: ...pipes and combustion chamber are clean Flue outlet pipes are clean 15 Frequently Asked Questions The following answers are tentative For more details use the instruction manual What is need to prepare...

Страница 18: ...f the pellet stove has not worked for a long time Can you use other types of fuel than wood pellets NO Pellet stove is designed to work with wood pellets with a diameter of 6 mm The use of another typ...

Страница 19: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 19...

Страница 20: ...Victoria 05 Ltd 20...

Страница 21: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 21...

Страница 22: ...Victoria 05 Ltd 22...

Страница 23: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 23...

Страница 24: ...ass sealing set 11 Combustion chamber set 12 Fire grate 13 Deflector top 14 Handle 15 Fire door set 16 Ashtray 17 Grill for hopper 18 Left side plate set 19 Right side plate set 20 Special tool 21 Dis...

Страница 25: ...the remaining population For other countries please contact you dealer Any warranty repair of the pellet stove is recorded in the diary of warranty Warranty of the pellet stove is NOT VALID in the fol...

Страница 26: ...Victoria 05 Ltd 26 DIARY for repairs under warranty Company Receipt date Type of repair Delivery date Carried out...

Страница 27: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 27...

Страница 28: ...Victoria 05 Ltd 1B Ivan Momchilov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 fax 359 618 60200 e mail info v05 bg http www v05 bg...

Отзывы: