background image

Victoria-05 Ltd.

 

 

 

10 

 

10.2.1. Main user control panel. 

To visualize every function from the  display it is necessary to touch the respective icon. The blue arrow in the sub menu is for 
returning  to  the  previous  screen.  By  pressing SAVE  all  corrections  are  saved.  The  left  and right  arrows  are  for  decreasing  and 
increasing the value of the respective parameter.

 

 

Display symbol 

Description 

00/00/0 
Date display 

day/month/year 

00 : 00 
Hour display 

Hour : Minutes 

 
 

 
 
 
 

Indoor temperature 
 
 
 

The number in the rectangle displays the current (momentary) indoor temperature. The number 
in the circle displays the temperature that is set to maintain in the room. 
When the icon with the number of the indoor temperature is touched, an additional page would 
open, where the user can set the preferred temperature(min.10

о

С-max.40

о

С).In the upper right 

angle a sun symbol displays that the user sets the daily indoor temperature. 

If a moon symbol displays, then the temperature to set 
is for the night. 
Entering the temperature is done through the Left and 
Right icons. Saving the value is done by pressing Save. 

After pressing it a green bar will be shown low down, which have to fill up, and then it would 
disappear. This shows that the value has been saved correctly! During saving, access to the Back 
Icon is denied to prevent involuntary interruption of the save process. The icon latter will re-
appear after the process has been finished. 
If for more than 6 seconds - there is no connection to the Control Unit, the value will not be saved! 

 

 

 
Day time and night time 
temperatures 
 

 

To change the required day and night temperature it’s necessary to touch the “house” icon. Sun 
symbol for day time temperature and moon symbol for night time temperature. Additional page 
will be displayed where the user can determinate the desired temperatures and hour range. When 

touching the hour shown under the day and night icons a new page 
is opened, where we can change the hour.   
Day time is with range 4:00 till 17:00 h 
Night time is with range 18:00 till 23:00 h 

 
 

indoor fan 

When the fan is not operational, the display icon is static. When the fan is operational, the icon 
starts  rotating.    When  started,  in  the  rectangle  next  the  icon  is  show  AUTO  that  indicates  for 
automatic mode. During auto mode, the fan speed is controlled automatically depending from 
the  position  in  the  programmed  cycle.  When  the  field  is  pressed,  the  numbers  1,  2  and  3  are 
shown one after another. Every one of them is showing on which modulation we would like to 
operate the fan.  

Manual feed 

Pressing the icon activates the feed screw and remains in this mode until the icon is released. It is 
visible only during “ready mode”. When the pellet stove is started, it will disappear! 

Main menu and 
service settings 

When the icon is touched, a new page with the main menu is opened.  

10.2.2. Types of modes of the control unit. 

 

Ready mode 

 

 

Warm up 

 

Start  

 

Modulation (Р1,Р2 и Р3) 

 

Feeding/Loading 

 

Cleaning 

 

Ignition 

 

ECO mode 

Содержание VITTORIA 10

Страница 1: ...INSTRUCTION MANUAL for installation and operation of air pellet stove VITTORIA 8 VITTORIA 10...

Страница 2: ...E CONTROL UNIT 10 10 2 3 MAIN MENU 11 10 2 4 INSTALLER SETTINGS 12 10 2 5 SERVICE TECHNICIAN SETTINGS 13 10 3 COLD TEST 14 11 INSTRUCTION MANUAL 14 11 1 WOOD PELLETS LOADING 14 11 2 WOOD PELLET REFUEL...

Страница 3: ...of failure of any of its components Safety components are activated without outside interference Necessary for the proper operating of the pellet stove is its proper installation in accordance with t...

Страница 4: ...Victoria 05 Ltd 4 3 Technical data and dimensions Drawing 1...

Страница 5: ...pellets with calorific value not less than 4300 ccal kg and heat loss of heated room 33 ccal m h Consideration must be given to the availability of external devices that can influence the operation o...

Страница 6: ...outlet and intakes combustion air by vacuum Gear motor Driven auger screw by means of which the pellets are conveyed from the pellet fuel hopper to the combustion chamber Room air fan Ensures additio...

Страница 7: ...from Picture 2 Through the control panel the user can visualize and manage all stages of the operation of the pellet stove 8 Fuel Pellet stove e designed and programmed to burn wood pellets They have...

Страница 8: ...o the timber wall or other inflammable material suitable materials such as ceramic wool should be used to isolate it Fresh air opening Imperative to ensure submission of fresh air The room in which is...

Страница 9: ...after installation to make a detailed instruction of the user Pellet stove is coated by high temperature resistant paint but not against corrosion In case of accumulation of dust surfaces can be clean...

Страница 10: ...appear after the process has been finished If for more than 6 seconds there is no connection to the Control Unit the value will not be saved Day time and night time temperatures To change the require...

Страница 11: ...h Intermediate clean indicates the time left before the system starts cleaning mode Recommended value 600 Pellets indicates the volume of the pellets used during operation mode Input value is gr min D...

Страница 12: ...have to be touched to unlock the display 10 2 4 Installer settings Types of settings for Installer entered with installer password Factory settings Vittoria 8 Vittoria 10 Duration 700 sec 700 sec Fan...

Страница 13: ...s how often the cleaning procedure has to be triggered The set value is summed up from the feed screw working time By this way it s possible to set the cleaning based on the calculation of the amount...

Страница 14: ...me runs out the mode is changed to feeding loading In this mode again a time counter is shown The default time is 70 sec The smoke fan is reducing the power The screw is activated and starts loading i...

Страница 15: ...ny scales that clog the holes Picture 6 Vacuum clean the combustion chamber and all contact edges Clean the glass when it is cold If necessary use appropriate detergent Never vacuum hot coals because...

Страница 16: ...as stopped working Error messages are described below Do not unplug the pellet stove from the main electrical supply during shutdown process In case of failure To restart the pellet stove is necessary...

Страница 17: ...pipes and combustion chamber are clean Flue outlet pipes are clean 15 Frequently Asked Questions The following answers are tentative For more details use the instruction manual What is need to prepare...

Страница 18: ...f the pellet stove has not worked for a long time Can you use other types of fuel than wood pellets NO Pellet stove is designed to work with wood pellets with a diameter of 6 mm The use of another typ...

Страница 19: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 19...

Страница 20: ...Victoria 05 Ltd 20...

Страница 21: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 21...

Страница 22: ...Victoria 05 Ltd 22...

Страница 23: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 23...

Страница 24: ...ass sealing set 11 Combustion chamber set 12 Fire grate 13 Deflector top 14 Handle 15 Fire door set 16 Ashtray 17 Grill for hopper 18 Left side plate set 19 Right side plate set 20 Special tool 21 Dis...

Страница 25: ...the remaining population For other countries please contact you dealer Any warranty repair of the pellet stove is recorded in the diary of warranty Warranty of the pellet stove is NOT VALID in the fol...

Страница 26: ...Victoria 05 Ltd 26 DIARY for repairs under warranty Company Receipt date Type of repair Delivery date Carried out...

Страница 27: ...12 2018 INSTRUCTION MANUAL for installation and operation of pellet stove VITTORIA 8 VITTORIA 10 27...

Страница 28: ...Victoria 05 Ltd 1B Ivan Momchilov Str 5100 Gorna Oryahovitsa Republic of Bulgaria phone 359 618 60282 fax 359 618 60200 e mail info v05 bg http www v05 bg...

Отзывы: