AVX-10K Operation
Rev. 002
2022-08-25
22135254
VIAVI
Page
104
of
139
BEARING
This field depends on the setting of BEARING STEP. If BEARING STEP is FIXED, the
UP/DOWN Arrow keys will update the value in 30-degree increments. Clicking in
the center of the control will allow direct selection of a Bearing value from 0 to 330
degrees.
If BEARING STEP is VARIABLE, the UP/DOWN Arrow keys will update the value in
degree increments based on BEARING STEP SIZE. BEARING STEP SIZE is selected by
clicking in the center of the control. Values can be 0.1, 1.0, 10.0, and 100.0. Range
is from 0.0 to 360.0 degrees.
TONE CONTROL
Allows selection between OFF, TONE, and MORSE.
M MOD
Clicking in the center of this control opens a window with slider controls to allow
adjustment of the Master Modulation Depth in 2% offsets from 0 to 110%. The
Master Modulation control functions as a multiplier of the individual modulation
components. The Master Modulation Depth is the sum of the Depths of
Modulation (SDM) of the individual tone components.
TONE DELETE
This field allows the 30 Hz Reference, 30 Hz Variable, or both to be deleted. Press
anywhere on this control for the popup selection window.
30 Hz MOD
This field controls the value of the 30 Hz Variable Phase modulation depth. Use the
UP/Down Arrow keys to adjust the value in 1% steps or click the center of the
control to popup a slide to select the value. Range is 0 to 30%.
9960 Hz MOD
This field controls the value of the 9960 Hz Variable Phase modulation depth. Use
the UP/Down Arrow keys to adjust the value in 1% steps or click the center of the
control to popup a slide to select the value. Range is 0 to 30%.
Revert To Normal
button: If any parameters have been changed and the indicators show “UNCAL”,
this softkey will appear. Pressing this button will “zero” all parameters back to their normal state.
6.3. Distance Measuring Equipment (DME)
6.3.1. Unique Setup
Refer to Chapter 3 for common setup items. The settings unique to the DME application are described
in the table below.
Содержание AVX-10K
Страница 1: ...AVX 10K Flight Line Test Set Operations Manual ...
Страница 17: ...AVX 10K Operation Rev 002 2022 08 25 22135254 VIAVI Page 15 of 139 Figure 6 Side View ...
Страница 86: ...AVX 10K Operation Rev 002 2022 08 25 22135254 VIAVI Page 84 of 139 ...
Страница 88: ...AVX 10K Operation Rev 002 2022 08 25 22135254 VIAVI Page 86 of 139 ...
Страница 109: ...AVX 10K Operation Rev 002 2022 08 25 22135254 VIAVI Page 107 of 139 ...