AVX-10K Operation
Rev. 002
2022-08-25
22135254
VIAVI
Page
55
of
139
3.2.7.
Advanced Settings
•
Check All UUT Capability –
for Transponder and ADS-B applications, all test parameters the UUT
is capable of will be tested. This is typically always set to Yes.
•
ADS-B Auto DF Setting –
Choose DF17 (typical – for Mode S transponders) or DF18 (1090MHz
emitters). Most often this should be left as DF17. The DF18 option is used for beacons placed
on obstacles around airports or in vehicles that are travelling around aircraft.
•
Position Decode –
Choose Global (most common, decodes two consecutive squitters to
determine position) or Local (uses one squitter and entered GPS LAT/LON position to determine
position)
•
Verify Unit Setup Configuration –
when set to YES, this will cause a pop-up screen to appear
after the RUN button is selected, allowing the user to verify the AVX-10K is set up correctly prior
to running the test. Setting this to NO will disable this popup screen.