Network bay interconnect cables provided (Qty. 1 P/N 514642, Qty. 1 P/N 514639).
♦
Expandable either left or right.
Restrictions
The system must consist of one (1) primary power/distribution bay or primary power only bay and may consist of up to seven
(7) additional bays. These additional bays may be a combination of secondary power/distribution bays, secondary power only
bays, and/or distribution only bays (maximum of 4 distribution only bays per system).
Ordering Notes
1)
(208 VAC Input).
2)
Order rectifiers as required per
(480 VAC Input) or
(208 VAC Input).
3)
Order distribution fuse and/or circuit breaker devices as required per
in the
ACCESSORY
DESCRIPTIONS
section.
4)
List 11: Order additional MCA customer alarm relay circuit card(s) as required per
, and optional MCA I/O circuit
cards per
. Order optional LMS Expansion CPU circuit card and LMS options as required per
, and
SAG586505000. Also order additional LMS Network cables as required per
Replacement/Additional LMS Network
5)
Order bay grounding lugs as required per
Power/Distribution Bay Frame Grounding Wire Sizes and Lugs
in the
ACCESSORY DESCRIPTIONS
section.
6)
Order load distribution lugs as required per
Power/Distribution Bay and Distribution Only Bay Load Distribution Wire
in the
ACCESSORY DESCRIPTIONS
section.
7)
Order battery cable lugs as required per
Power/Distribution Bay Battery Cable Sizes and Lugs
in the
ACCESSORY
DESCRIPTIONS
section.
8)
Order AC input lugs as required per
Power/Distribution Bay AC Input, Ten (10) Rectifier Feeds Wire Sizes, Branch Circuit
in the
ACCESSORY DESCRIPTIONS
section.
9)
Order internal ground busbar assembly, external top-mount battery input busbar assembly, busbar shield kit, external
top-mount ground (load return) busbar assembly, and/or load return lug extension busbar assembly as required per the
appropriate sections located under
10)
If secondary bays are placed on both sides of the primary bay, a different length Network cable is required that connects
a secondary bay on one side with a secondary bay on the other side. Order per
Replacement/Additional Network Cables
11)
Side cover panels are provided with primary bays. These cover panels are used with secondary bays when bays are
placed next to each other. In installations where a secondary bay is placed by itself, order (1) of each of the following side
cover panels per exposed side: P/N 514482 and P/N 514484.
List 12 and 112: Secondary Power/Distribution Bay (Common Equipment)
Features
♦
Provides common equipment for one (1) “power and distribution” bay rated for up to 2400 amperes.
♦
Mounted in a 7'0"H x 24"W x 30"D box framework.
♦
Provides ten (10) rectifier mounting positions.
♦
Provides forty-eight (48) distribution device mounting positions.
♦
Provides two (2) buses of distribution. When used with the MCA, each bus contains a monitoring circuit card; which can
be set for no group designation, Group A designation, or Group B designation.
♦
Configured for a 4000 A internal bus or external main battery termination bars.
♦
Includes a router or CAN interface assembly for bay communication to the controller/monitor in the primary power bay.
♦
List 12: Provides mounting for optional LMS Expansion CPU circuit card. Provides a seven-slot card cage for mounting
MCA customer alarm relay circuit cards, MCA I/O circuit cards, and/or optional LMS I/O circuit cards.
♦
List 112: Includes the SM-DUE. Refer to “
♦
Network bay interconnect cables provided (Qty. 1 P/N 514643, Qty. 1 P/N 509900).
♦
Expandable either left or right.
♦
Surge suppression optional.