282
Firmware Version 5.4
Possible Cause:
The display has detected that the crop type specified in the CEBIS monitor has
changed to a crop type that is different than what is specified in the display’s field operation
configuration.
Either:
Solution:
1. Change the crop type specified in the CEBIS monitor back to what is specified
in the display. Then reload the display’s field operation configuration.
Or
Solution:
2. Create a new field operation configuration that includes the new crop type. If
necessary, create a new Harvest Product in Product Setup with the Harvest Crop Wizard.
For more information, see
“Grain Harvest Settings” on page 23
Error Message:
Grain Calibration: “A new grain calibration has been detected. Select an operating
configuration to continue.”
Possible Cause:
When a new calibration is started in the CEBIS monitor, the warning at left
appears on the display. At the same time, the display unloads the Field Operating Configuration
that was collecting data with the old calibration.
Solution:
Acknowledge the warning by pressing
. At the Home screen, press the
Select Event
button. Use the Field Operation Wizard to create a new field operation
configuration. After receiving the new calibration from the CEBIS monitor, the display will
calculate that field operation configuration’s harvest data by using this new calibration
that was sent from CEBIS. (Also discussed in
“Calibration Information” on page 278
).
Error Message:
CLAAS Communication Error: “Cannot communicate with CLAAS bridge module.”
Possible Cause:
No communication between Bridge Module and CLAAS CAN-Bus. (Shown as
Indicator Light
C
).
Solution:
Check cabling between Module and CLAAS Can-Bus.
Error Message:
CAN Node Lost: “AL Bridge Node has stopped communicating.”
Possible Cause:
No communication between Bridge Module and display. (Shown as Indicator Light
A
).
Solution:
Check cabling between Bridge Module and display.
Содержание ag leader
Страница 1: ...Operators Manual Firmware Version 5 4 Ag Leader PN 4002722 Rev G ...
Страница 2: ...Firmware Version 5 4 ...
Страница 20: ...6 Firmware Version 5 4 ...
Страница 38: ...24 Firmware Version 5 4 For more information see Legend Settings on page 52 ...
Страница 55: ...41 SETUP M ANAGEMENT S ETUP Remove button Press to remove a business ...
Страница 56: ...42 Firmware Version 5 4 ...
Страница 78: ...64 Firmware Version 5 4 ...
Страница 82: ...68 Firmware Version 5 4 Press to Export All Log files Export All Log Files ...
Страница 84: ...70 Firmware Version 5 4 ...
Страница 94: ...80 Firmware Version 5 4 ...
Страница 108: ...94 Firmware Version 5 4 ...
Страница 140: ...126 Firmware Version 5 4 ...
Страница 154: ...140 Firmware Version 5 4 ...
Страница 158: ...144 Firmware Version 5 4 ...
Страница 162: ...148 Firmware Version 5 4 ...
Страница 222: ...208 Firmware Version 5 4 ...
Страница 244: ...230 Firmware Version 5 4 ...
Страница 260: ...246 Firmware Version 5 4 ...
Страница 289: ...275 HARVEST H ARVEST M ONITORING M APPING Motor Current Measure of Elevator Mount Unit EMU current shown in amps ...
Страница 290: ...276 Firmware Version 5 4 ...
Страница 304: ...290 Firmware Version 5 4 ...