Strip Till Control Screen
• Product Density
This density value (shown in pounds per cubic foot, or
lb./ft.3), is stored with each product. Press
to
edit value.
Note: For proper machine performance and accuracy. Product Density should be measured for every
application load.
• Conveyor 1 Rate
This setting represents the volume of product dispensed by one revolution of the conveyor drive shaft (cubic
foot per revolution, or ft.3 /rev.) This number is shown with the assumption that the conveyor shaft has a 1-
inch gate opening.
CAUTION: You must either manually enter conveyor rate value or perform a CFR calibration routine for
each product and channel combination, otherwise misapplication will occur.
• Static Calibration
Press the
Static Calibration
button to perform an automated routine to calibrate each metering circuit. This
calibration is performed before applying in field conditions. For more information, see
Procedure for Hydraulic Drive systems” on page 259
• In-Field Calibration
Press the
In-Field Calibration
button to perform an automated routine to adjust the calibration number for
the selected metering circuit. This calibration is performed if there is a difference between the amount of
product logged as compared to what was actually applied. For more information, see
Procedure (Strip Till)” on page 261
.
Static CFR Calibration Procedure for Hydraulic Drive systems
You must perform a calibration for each granular product control channel (bin) for the equipment
configuration before applying in field conditions. This process is outlined below and on the following
page. The Static CFR Calibration Procedure performs an automated routine to calibrate each metering
circuit.
Press: Map button > Strip Till Control button > Static Calibration button
Channel 1
Channel 2
Channel 3
Prime
58 lb/ft
3
0.256 ft
3
/rev
DAP
Strip Till Control
Product
Density
Conveyor
Rate
Static
Calibration
In-Field
Calibration
3500
1
RPM
2
3
20
15
15
Static
Calibration
Содержание ag leader
Страница 1: ...Operators Manual Firmware Version 5 4 Ag Leader PN 4002722 Rev G ...
Страница 2: ...Firmware Version 5 4 ...
Страница 20: ...6 Firmware Version 5 4 ...
Страница 38: ...24 Firmware Version 5 4 For more information see Legend Settings on page 52 ...
Страница 55: ...41 SETUP M ANAGEMENT S ETUP Remove button Press to remove a business ...
Страница 56: ...42 Firmware Version 5 4 ...
Страница 78: ...64 Firmware Version 5 4 ...
Страница 82: ...68 Firmware Version 5 4 Press to Export All Log files Export All Log Files ...
Страница 84: ...70 Firmware Version 5 4 ...
Страница 94: ...80 Firmware Version 5 4 ...
Страница 108: ...94 Firmware Version 5 4 ...
Страница 140: ...126 Firmware Version 5 4 ...
Страница 154: ...140 Firmware Version 5 4 ...
Страница 158: ...144 Firmware Version 5 4 ...
Страница 162: ...148 Firmware Version 5 4 ...
Страница 222: ...208 Firmware Version 5 4 ...
Страница 244: ...230 Firmware Version 5 4 ...
Страница 260: ...246 Firmware Version 5 4 ...
Страница 289: ...275 HARVEST H ARVEST M ONITORING M APPING Motor Current Measure of Elevator Mount Unit EMU current shown in amps ...
Страница 290: ...276 Firmware Version 5 4 ...
Страница 304: ...290 Firmware Version 5 4 ...