76
VTK-VS-BA-015e-A | User Manual MDS 3200+ Series
|
Communication Interfaces
To delete a scenario use the version SCENARIO:SAVE:<value>:-
Example:
Input:
SCENARIO:SAVE:1:0,15,1,2,5,2,3,5,3,4,5,0,5,5,1,6,50,2,7,50,3,
8,50,0,9,50,1,10,50
Result:
The scenario parameters of scenario 1 are saved.
Return:
OK
65
SCENARIO:READ:<scenario no.>
Description:
This command gives you the scenario parameters of the named scenario
via the serial interface. The response follows the scheme “setup no. of set-
up 1, number of pulses of setup 1, scenario delay of setup 1, setup no. of
setup 2, NP of setup 2, sc. delay of setup 2, …, sc. delay of setup 10”. The
scenario delay is given in 1/10 ms. The value 50 e.g. would represent 5 ms.
In case not all setups are used, the others are left-out in the output.
Example:
Input:
SCENARIO:READ:<1>
Result:
Gives the scenario parameters of scenario 1.
Return:
0,1,5,1,2,5,2,3,5,3,4,5,0,5,5,1,6,50,2,7,50,3,8,50,0,9,50,1,10,50
66
SETUP:SAVE:<Setup-Nr.>:<Rising>,<Open Time>,<Falling>,<Needle Lift>,<Number of Pulses>,
<Delay>
Description:
This command saves the given parameters in a setup. You always have to
provide the number of the setup and all six setup parameters.
All parameters will be checked. Not enough parameters or delay too short
with activated heater will lead to cancellation. Otherwise the parameters
will be corrected to within acceptable limits.
Parameters relating to time have to be specified in 1/10 ms, except for “Fall-
ing“, which has to be entered in 1/100 ms. Values lower than “1” are not
admissible. Therefore the minimum falling value amounts to 0,01 ms
(10 %
NL)
, the minimum rising value is 0,1 ms
(30 % NL)
.
Specified values must be integer and positive.
Example:
Input:
SETUP:SAVE:1: 30,10,15,90,20,8
Result:
The parameters will be saved in the given setup and checked.
Return:
OK
67
SETUP:ASAVE:<Setup-Nr.>:<Rising>,<Open Time>,<Falling>,<Needle Lift>,<Number of Puls-
es>, <Delay>
Description:
This command saves the given parameters in a setup. You always have to
provide the number of the setup and all six setup parameters.
All parameters will be checked. Not enough parameters or delay too short
with activated heater will lead to cancellation. Otherwise the parameters
will be corrected to within acceptable limits.
Parameters relating to time have to be specified in 1/10 ms, except for “Fall-
ing“ and “Rising”, which have to be entered in 1/100 ms. Values lower than
“1” are not admissible. Therefore the minimum falling value amounts to
0,01 ms
(10 % NL)
, the minimum rising value is 0,01 ms
(1 % NL)
.
Specified values must be integer and positive.
Example:
Input:
SETUP:ASAVE:1: 30,10,15,90,20,8
Result:
The parameters will be saved in the given setup and checked.
Return:
OK
Содержание MDS 3200+ Series
Страница 1: ......
Страница 117: ...VTK VS BA 015e A User Manual MDS 3200 Series Attachments 117 13 ATTACHMENTS 13 1 EC Declaration of Conformity...
Страница 118: ...118 VTK VS BA 015e A User Manual MDS 3200 Series Attachments 13 2 Dimensional Drawing MDC 3200...
Страница 119: ...VTK VS BA 015e A User Manual MDS 3200 Series Attachments 119 13 3 Dimensional Drawing MDV 3200A...
Страница 120: ...120 VTK VS BA 015e A User Manual MDS 3200 Series Attachments 13 4 F Dimensional Drawings MDV 3200F...
Страница 121: ...VTK VS BA 015e A User Manual MDS 3200 Series Attachments 121...
Страница 122: ...122 VTK VS BA 015e A User Manual MDS 3200 Series Attachments 13 5 Connection Diagram PLC Interface...