38
VTK-VS-BA-015e-A | User Manual MDS 3200+ Series
|
Initial Operation
Step 2:
Unscrew the nozzle unit from the fluid box
(counter-clockwise)
. Use tool MDT 302 or
MDT 301. Confirm by pressing
[enter]
.
The Display now shows “500 Shots – Please Wait”. These shots
help to prepare the valve for the adjust.
Wait till a new message on the display announces the next step.
Step 3:
In the display appears “Adjust Nozzle – Enter if green”.
After a few seconds the initial message disappears from the display. Instead the current val-
ue is shown. At first it will be roughly between 960 and 985. Screw the nozzle unit towards
the fluid box
(clockwise)
.
Keep turning till the red adjust LED is ON. The value shown in the display should be about
1100.
IMPORTANT NOTE!
(Upper Limit)
Maximum admissible display value is 1250. Otherwise the tappet could break.