VTK-VS-BA-015e-A | User Manual MDS 3200+ Series
|
Communication Interfaces
75
Return:
Scenario: OFF
PLCSTOP Scenario 1: OFF
PLCSTOP Scenario 2: OFF
PLCSTOP Scenario 3: OFF
PLCSTOP Scenario 4: OFF
60
SCENARIO:OFF
Description:
This command deactivates the use of scenarios.
Example:
Input:
SCENARIO:OFF
Result:
Use of scenarios is deactivated.
Return:
OK
61
SCENARIO:ON
Description:
This command activates the use of scenarios.
Example:
Input:
SCENARIO:ON
Result:
Use of scenarios is activated.
Return:
OK
62
SCENARIO:PLCSTOP:<scenario no.>:OFF
Description:
This command deactivates the PLC-Stop. The number of the scenario can
either be 1, 2, 3 or 4.
Example:
Input:
SCENARIO:PLCSTOP:1:OFF
Result:
PLC-stop for scenario 1 is deactivated.
Return:
OK
63
SCENARIO:PLCSTOP:<scenario no.>:ON
Description:
This command activates the PLC-stop of a scenario. The number of the
scenario can either be 1, 2, 3 or 4.
Example:
Input:
SCENARIO:PLCSTOP:1:ON
Result:
PLC-stop for scenario 1 is activated.
Return:
OK
64
SCENARIO:SAVE:<Scenario-Nr.>:<Scenario 1 Setup, Scenario 1 Number of Pulses, Scenario
1 Delay, Sc. 2 Setup, Sc. 2 NP, Sc. 2 Dl., Sc. 3 Setup, Sc. 3 NP, Sc. 3-Dl., Sc. 4 Setup, Sc. 4 NP,
Sc. 4-Dl., Sc. 5 Setup, Sc. 5 NP, Sc. 5-Dl., Sc. 6 Setup, Sc. 6 NP, Sc. 6-Dl., Sc. 7 Setup, Sc. 7 NP,
Sc. 7 Dl., Sc. 8 Setup, Sc. 8 NP, Sc. 8 Dl., Sc. 9 Setup, Sc. 9 NP, Sc. 9 Dl., Sc. 10 Setup, Sc. 10
NP, Sc. 10 Dl.>
Description:
This command saves the parameters of the given scenario. You only have to
enter parameters for the setup actually used. For every such setup you have
to give the setup-number, the number of pulses and the scenario delay.
The parameters will be checked. Not enough parameters or illegal ones will
result in cancellation; therefore you always have to enter complete sets of
setup number, NP and Sc. delay. You can enter a maximum of ten such sets.
The scenario number can be 1, 2, 3 or 4, a setup-number 0, 1, 2 or 3.
The NP can be between 1 and 32000 or 0, which would mean “infinite”.
The scenario delay will be given in 1/10 ms, i.e. 5 means 0,5 ms. The max
delay is 1000,0 ms, min is 0,1 ms
(with heater 2,0 ms)
.
Содержание MDS 3200+ Series
Страница 1: ......
Страница 117: ...VTK VS BA 015e A User Manual MDS 3200 Series Attachments 117 13 ATTACHMENTS 13 1 EC Declaration of Conformity...
Страница 118: ...118 VTK VS BA 015e A User Manual MDS 3200 Series Attachments 13 2 Dimensional Drawing MDC 3200...
Страница 119: ...VTK VS BA 015e A User Manual MDS 3200 Series Attachments 119 13 3 Dimensional Drawing MDV 3200A...
Страница 120: ...120 VTK VS BA 015e A User Manual MDS 3200 Series Attachments 13 4 F Dimensional Drawings MDV 3200F...
Страница 121: ...VTK VS BA 015e A User Manual MDS 3200 Series Attachments 121...
Страница 122: ...122 VTK VS BA 015e A User Manual MDS 3200 Series Attachments 13 5 Connection Diagram PLC Interface...