Table 1-3
System Status LED states
(continued)
Description
Criticality
State
Color
Non-fatal, although the system is likely to fail due
to the following issues:
■
Critical threshold crossed – Voltage,
temperature (including HSBP temp), input
power to power supply, output current for
main power rail from power supply and
PROCHOT (Therm Ctrl) sensors.
■
VRD Hot asserted
■
Minimum number of fans to cool the system
not present or failed
■
Hard drive fault
■
Power Unit Redundancy sensor – Insufficient
resources offset (indicates not enough power
supplies present)
■
Correctable memory error threshold has been
reached for a failing DIMM when the system
is operating in a non-redundant mode.
Non-critical
The system is
operating in a
degraded state
with an
impending failure
warning.
However, the
system is still
functioning.
~1 Hz blink
Amber
Fatal alarm – system has failed or shutdown:
■
CPU CATERR signal asserted
■
MSID mismatch detected (CATERR also
asserts for this case)
■
CPU1 is missing
■
CPU Thermal Trip
■
No power – power fault
■
DIMM failure when there is only one DIMM
present; no other good DIMM memory
present
■
Runtime memory uncorrectable error in
non-redundant mode.
Critical,
non-recoverable
– System is
halted
Solid on
Amber
13
Hardware overview
About the 5250 Appliance control panel
Содержание 5250
Страница 1: ...Veritas 5250 Appliance Hardware Installation Guide ...
Страница 46: ...46 Installation procedures Connecting an appliance to more than one storage shelf ...
Страница 47: ...47 Installation procedures Connecting an appliance to more than one storage shelf ...
Страница 53: ...53 Installation procedures Connecting an appliance to more than one storage shelf ...
Страница 151: ...V Veritas Remote Management interface accessing 70 151 Index ...