Table 1-3
System Status LED states
(continued)
Description
Criticality
State
Color
System degraded:
■
Redundant loss, such as power supply or
fan. Applies only if the associated platform
sub-system has redundancy capabilities.
■
Fan warning or failure when the number of
fully operational fans is more than minimum
number needed to cool the system.
■
Non-critical threshold crossed: Temperature
(including HSBP temp), voltage, input power
to power supply, output current for main
power rail from power supply and Processor
Thermal Control (Therm Ctrl) sensors.
■
Power supply predictive failure occurred while
redundant power supply configuration was
present.
■
Unable to use all of the installed memory (one
or more DIMMs failed/disabled but functional
memory remains available).
■
Battery failure
■
BMC executing in uBoot. (Indicated by
Chassis ID blinking at 3Hz). System in
degraded state (no manageability). BMC
uBoot is running but has not transferred
control to the BMC Linux. Server will be in
this state 6-8 seconds after BMC reset while
it pulls the Linux image into flash.
Degraded
The system is
operating in a
degraded state
although still
functional.
or
The system is
operating in a
redundant state
but with an
impending failure
warning.
~1 Hz blink
Green
System degraded (continued):
■
BMC booting Linux. (Indicated by Chassis ID
solid ON). System in degraded state (no
manageability). Control has been passed
from BMC uBoot to BMC Linux itself. It will
be in this state for 10-20 seconds.
■
BMC Watchdog has reset the BMC.
■
Power unit sensor offset for configuration
error is asserted.
■
Hard disk drive HSC is off-line or degraded.
Degraded
(continued)
~1 Hz blink
Green
12
Hardware overview
About the 5250 Appliance control panel
Содержание 5250
Страница 1: ...Veritas 5250 Appliance Hardware Installation Guide ...
Страница 46: ...46 Installation procedures Connecting an appliance to more than one storage shelf ...
Страница 47: ...47 Installation procedures Connecting an appliance to more than one storage shelf ...
Страница 53: ...53 Installation procedures Connecting an appliance to more than one storage shelf ...
Страница 151: ...V Veritas Remote Management interface accessing 70 151 Index ...