7. Maintenance
7-15
ROBOT HP7C / HP10C / HP15C / HP17C
© VEMAG 2004
1
Assembly bolt
2
Blow-out cover
3
Seal
Fig. 7-16
Removing the blow-out
cover (deoiler side)
1
2
3
1
Assembly bolt
2
Cover
3
Seal
Fig. 7-17
Removing the cover
(deoiler housing)
1
2
3
There are two screens in the blow-out cover of the deoiler side which have
to be checked for contamination and cleaned.
• Undo the two assembly bolts (1) and remove blow-out cover (2) and seal
(3).
• Clean the screens by blowing them out. If they are severely
contaminated, replace them.
• Undo the six assembly bolts (1) and remove front cover (2) and seal (3).