4. Setting up
ROBOT HP7C / HP10C / HP15C / HP17C
4-1
© VEMAG 2004
4. Setting up
4.1 General information
• To set up the machine, select a double screw housing, the double
screws to suit the product to be processed and the required
accessories.
Danger!
To prevent injury, switch off the machine before setting up. Then switch off
the main switch to disconnect the machine from the mains.
4.2 Fitting the double screw housing
Danger!
There is a risk of crushing when fitting and removing the double screw
housing and the double screws. To prevent injury, proceed extremely
carefully when fitting and dismantling these parts.
The machine is fitted with an all-in-one or a two-part double screw
housing.
• All-in-one double screw housing:
push double screw housing (1) right into the feed cylinder of the
machine. Inlet bore (2) for product and vacuum should face upwards.
• Two-part double screw housing:
first push the rear, longer part of the housing with the inlet bore for
product and vacuum upwards right into the feed cylinder of the
machine. Then push the front, shorter part of the housing into the feed
cylinder up to the stop.
2
1
1 Double screw housing
2 Inlet bore
Fig. 4-1
Installing double screw
housing