7. Maintenance
7-14
ROBOT HP7C / HP10C / HP15C / HP17C
© VEMAG 2004
1
Angled flange
2
Seal
3
Screen
4
O-ring
Fig. 7-14
Cleaning the screen
(intake air side)
1
2
3
4
1
Valve disc
2
Compression spring
3
Valve guide
Fig. 7-15
Assembling the angled
flange (intake air side)
1
2
3
• Remove angled flange (1) and seal (2).
• Take the valve guide, compression spring and valve disc out of the
angled flange.
• Clean screen (3) by blowing it out. If it is severely contaminated, replace
it.
• Replace O-ring (4).
• Replace valve disc (1), compression spring (2) and valve guide (3) in the
angled flange.
• Fit the angled flange together with a new seal.