3. Installation and commissioning
ROBOT HP7C / HP10C / HP15C / HP17C
3-6
© VEMAG 2004
3.5 Levelling the lifting/tipping device (optional)
The trolley hoist of the lifting/tipping device is set at the factory with the
feet of the machine screwed in and on a level floor (outlet height 1,000
mm). If the feet of the machine are screwed out to adjust height or level
the machine in the horizontal plane, the stop parts on the lifting/tipping
device will have to be reset to obtain the correct height for the trolley.
Adjust the lifting/tipping device as follows:
• Make the machine absolutely level using the adjustable feet.
Section 3.2
• Undo the four mounting bolts (1) for the stop bar (2) of the trolley hoist
and push the bar right in.
• Switch on the machine and move the arm of the lifting/tipping device to
the vertical end position using the UP key.
1
2
1 Mounting bolts
2 Stop bar
Fig. 3-7
Stop
Содержание ROBOT HP7C
Страница 6: ...Index iv VEMAG 2004 ROBOT HP7C HP10C HP15C HP17C...
Страница 8: ...0 Foreword 0 2 VEMAG 2004 ROBOT HP7C HP10C HP15C HP17C...
Страница 20: ...2 Description ROBOT HP7C HP10C HP15C HP17C 2 8 VEMAG 2004...
Страница 30: ...3 Installation and commissioning ROBOT HP7C HP10C HP15C HP17C 3 10 VEMAG 2004...