8. Tighten the compression nut of the cable entry gland. The seal
ring must completely encircle the cable
9. Unscrew the blind plug on the Primary, screw in the supplied
cable gland
10. Connection cable to Primary, see steps 3 to 8
11. Screw the housing lid back on
The electrical connection is finished.
5.3 Single chamber housing
The following illustration applies to the non-Ex, Ex-ia and Ex-d-ia
version.
5 6 7
8
4
2
1
connect to Primary
Fig. 16: Wiring plan VEGABAR 86 Secondary Device
1 To the Primary Device
2 Ground terminal for connection of the cable screening
1)
Electronics and connec-
tion compartment
1) Connect shielding here. Connect ground terminal on the outside of the hous-
ing to ground as prescribed. The two terminals are galvanically connected.