data length 8 characters
a
Valve position after power up
0 = close
1 = open
b
Valve position after power failure
0 = close
1 = open
c
External isolation valve function
0 = no
1 = yes
d
Control stroke limitation
0 = no
1 = yes
e
Network failure end position
0 = valve will close
1 = valve will open
2 = valve stay on actual position
f
Slave offline position
0 = valve will close
1 = valve will open
2 = valve stay on actual position
g
Synchronization start
0 = standard
1 = special command
2 = open command
3 = all move commands
4 = always
h
Synchronization mode
0 = short
1 = full
This function does the valve configuration.
Setup function
Command
Acknowledgement
Description
SENSOR
CONFIGURATION
Set
s:01abcdefgh
s:01
Get
i:01
i:01abcdefgh