![VAT 653 Series Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/vat/653-series/653-series_installation-operating-and-maintenance-instructions_4123560033.webp)
Series 65
INSTALLATION
963283EA
Edition 2019-05-03
33/129
4.3.2.5
Power and sensor connection (
±
15 VDC sensors) with optional SPS module
[653 . . - . . A . - . . . . / 653 . . - . . C . - . . . . versions only]
•
VAT fuse recommendation: (a) 7 AF
•
Use shielded sensor cable(s). Keep cable as short as possible, but locate it away
from noise sources.
•
Connect Power supply (+24 / GND) at DA–15 male power connector and Sensors
(+15V / -15V / 0V / + / -) at DA–15 female sensor connector exactly as shown in
the drawing above!
•
Connector: Use only screws with 4–40 UNC thread for fastening the connectors!
Pins 4 and 11 must be
bridged for operation.
An optional switch
would allow for motor
interlock to prevent
valve from moving.
Low range sensor may be
connected to sensor 1 or
sensor 2 input. Do
configuration accordingly.
Содержание 653 Series
Страница 63: ...Series 65 INSTALLATION 963283EA Edition 2019 05 03 63 129 Example...
Страница 128: ...APPENDIX Series 65 128 129 Edition 2019 05 03 963283EA 13 Appendix No information entered on time...
Страница 129: ...Series 65 963283EA Edition 2019 05 03 129 129 This page left blank intentionally...