![VAT 653 Series Скачать руководство пользователя страница 46](http://html1.mh-extra.com/html/vat/653-series/653-series_installation-operating-and-maintenance-instructions_4123560046.webp)
INSTALLATION
Series 65
46/129
Edition 2019-05-03
963283EA
Analog sensors:
Sensor 1.Available = 1
Sensor 1.Enable = 1
Sensor 1.Range.Data Unit = Torr
Sensor 1.Range.Upper Limit Data Value = 1.0
Sensor 1.Range.Lower Limit Data Value = 0.0
Sensor 1.Range.Upper Limit Voltage Value = 10.0
Sensor 1.Range.Lower Limit Voltage Value = 0.0
Sensor 1.Range.Scale = Linear
Sensor 1.Input Source = Analog
Sensor 2.Available = 1
Sensor 2.Enable = 1
Sensor 2.Range.Data Unit = mTorr
Sensor 2.Range.Upper Limit Data Value = 100.0
Sensor 2.Range.Lower Limit Data Value = 0.0
Sensor 2.Range.Upper Limit Voltage Value = 10.0
Sensor 2.Range.Lower Limit Voltage Value = 0.0
Sensor 2.Range.Scale = Linear
Sensor 2.Input Source = Analog
0
-1
0
V
(
A
n
a
lo
g
i
n
te
rf
a
c
e
)
High range
sensor
Low range
sensor
0
-1
0
V
(
A
n
a
lo
g
i
n
te
rf
a
c
e
)
SENSOR 1 READING
0-100%
100 mTorr
1 Torr
0 mTorr
SENSOR 2 READING
0-10%
PRESSURE
0-100%