![VAT 653 Series Скачать руководство пользователя страница 70](http://html1.mh-extra.com/html/vat/653-series/653-series_installation-operating-and-maintenance-instructions_4123560070.webp)
INSTALLATION
Series 65
70/129
Edition 2019-05-03
963283EA
Inquiry function
Command
Acknowledgement
Description
DEVICE STATUS
Get
i:30
i:30abcdefgh
data length 8 characters
a
Access Mode
0 = local operation
1 = remote operation
2 = locked remote operation
b
Control Mode
1 = synchronization
2 = POSITION CONTROL
3 = CLOSED
4 = OPEN
5 = PRESSURE CONTROL
6 = HOLD
7 = LEARN
8 = INTERLOCK OPEN (by digital input)
9 = INTERLOCK CLOSED (by digital input)
C = power failure
D = safety mode
E = error (read «ERROR STATUS» for details)
c
Power Failure Option 0 = disabled
1 = enabled
d
Warning
0 = no warnings
1 = warnings
(read «WARNINGS» and «ERROR STATUS» for details)
efg Reserved
h
Simulation
0 = normal operation
1 = system simulation running
This function returns status information about the valve.
Remark: In simulation mode the valve can demonstrate pressure control capability
independent of other equipment such as vacuum chamber, flow controller and gauge.
Normal operation is not possible when simulation is running.