recommendation of 10W-30 engine oil is suitable for
operation in temperatures up to 104°F (40°C).
Extra care should be taken to keep the engine and air
compressor clean and to not restrict the air flow around
the unit.
5.8.2.2 MACHINE OPERATION
When operating the machine in high temperature areas,
precautions should be taken to prevent overheating. At
the minimum, all coolers, including air passage ways
around the coolers, should be free of debris and dirt. The
fan, driven by its own hydraulic motor, is designed to run
continuously to assure a constant flow of cooling air.
The operator should be aware that high temperatures
can influence engine performance, which can directly
effect some machine function capacity outputs.
5.8.3 HIGH DUST CONTENT OPERATION
5.8.3.1 ENGINE OPERATION
When the machine is to be used in continuously dusty
environments, special care must be taken with the
engine’s air cleaner and radiator. The intake air must be
cleaned with the air cleaner. Lowering of the radiator
cooling capacity due to clogging dust must be prevented.
If intake air resistance becomes higher, this will result in
reduced output. In order to maintain air tighten seals at
the joining sections of intake system component parts,
and thus to prevent foreign matter from entering, it is
necessary to ensure the security of the air intake system
to prevent the component parts from being damaged.
This can be accomplished by performing more frequent
TABLE 5F: REQUIREMENTS FOR HIGH TEMPERATURE OPERATION
Item
High 30° to 40°C (86° to 104°F)
Extremely high 40°C (104°F)
or higher
Combustion Fuel
Type No.2-D
(ASTM D975-94)
No.2-D
(ASTM D975-94)
Temperature
Lubrication Oil
Type
SAE #30, 10W30,15W40
SAE #40 or 20W50
Temperature
120°C (248°F) or lower
Cooling
Reserve tank
Normal operation allowance
Reduce load to 60%
Radiator, fan
Accessories Permissible
temperature Starter, regulator, alternator, relay, timer : 80°C (176°F) or lower
Emergency relay : 65°C (149°F) or lower
Temperature
Содержание 050518
Страница 14: ...GLOSSARY AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE XII 090012 OP_r0 BLANK PAGE...
Страница 54: ...SECTION 3 SPECIFICATIONS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 36 090012 OP_r0 BLANK PAGE...
Страница 138: ...SECTION 8 DIAGRAMS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 120 090012 OP_r0 BLANK PAGE...
Страница 141: ...AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM SECTION 9 ILLUSTRATED PARTS LIST 090012 OP_r0 PAGE 123 NOTES...
Страница 196: ...SECTION 9 ILLUSTRATED PARTS LIST AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM page 178 090012 OP_r0 BLANK PAGE...
Страница 208: ...APPENDIX B MAINTENANCE AND SERVICE LOG AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 190 090012 OP_r0 BLANK PAGE...
Страница 209: ...BLANK PAGE...