AIR IN ARC
®
300 SERIES ALL-IN-ONE POWER SYSTEM
®
SECTION 7: TROUBLESHOOTING
090012-OP_r0
PAGE - 113
COMPRESSOR (CONTINUED)
System operating pressure below
specified minimum (continued)
Inlet valve frozen shut
Repair/replace inlet valve. Refer to
Section
6.6.2, Repairing the Air Inlet Valve
.
Order
inlet valve repair kit—see
Table 9A:
Recommended Spare Parts List
.
Excess amount of oil in air
discharge
Machine not on level surface
Move machine to level surface.
Compressor oil level too high
The correct oil level is between the bottom
of the oil port threads (low level) to the top
lip of the port’s threads (high level). Drain
excess oil to correct level.
Tank not positioned with the drain at its
lowest point. Reposition machine.
NOTE:
Machine must be operated while on a level
surface in order for proper compressor oil
circulation throughout the system.
Scavenger system not operating
Inspect scavenger line for obstructions or
leaks. Replace if necessary.
Coaleser element plugged or damaged Replace the coalescer element. Consult
Section 6.6.6, Replacing the Spin-on Air/
Oil Coalescer
. Order replacement
coalescer element—see
Table 9A: Recom-
mended Spare Parts List
.
Excessive moisture in the
compressed air
Moisture accumulating in air tank
Drain water from air tank. Refer to
Section
6.6.9, Draining the Air Tank
.
WELDER
Welder and battery charger
behave erratically
Connection cables or receptacles are
soiled/contaminated
Check for twisted cables and/or soiled/
contaminated or loose receptacle
connections.
Untwist and/or straighten out any suspected
cable tensions. Carefully wipe off any
contaminants to receptacle connectors
before re-connecting. Replace any worn or
damaged cables or receptacles. Contact
Vanair
®
Mfg., Inc. Service Department if
behavior persists.
Welding function is not drawing enough
operating power
If running more than one function
simultaneously, turn off competing function.
No welder output
Fuse at welder field blown
Replace the welder field fuse. Refer to
Section 6.7,
Servicing the System Fuses
and Circuit Breakers
Continued on next page
7.2 TROUBLESHOOTING GUIDE
Fault/Malfunction
Possible Cause
Corrective Action
Содержание 050518
Страница 14: ...GLOSSARY AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE XII 090012 OP_r0 BLANK PAGE...
Страница 54: ...SECTION 3 SPECIFICATIONS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 36 090012 OP_r0 BLANK PAGE...
Страница 138: ...SECTION 8 DIAGRAMS AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 120 090012 OP_r0 BLANK PAGE...
Страница 141: ...AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM SECTION 9 ILLUSTRATED PARTS LIST 090012 OP_r0 PAGE 123 NOTES...
Страница 196: ...SECTION 9 ILLUSTRATED PARTS LIST AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM page 178 090012 OP_r0 BLANK PAGE...
Страница 208: ...APPENDIX B MAINTENANCE AND SERVICE LOG AIR N ARC 300 SERIES ALL IN ONE POWER SYSTEM PAGE 190 090012 OP_r0 BLANK PAGE...
Страница 209: ...BLANK PAGE...