90°
Gas cylinder and gas adjuster is not included with the
machine, and they needs to be prepared at customer’s
side as needed.
1
Connect the gas adjuster (with pressure reduce
valve and flow meter) to the gas cylinder.
2
Connect the flow meter to the gas cock of sealer
by vinyl hose. When gas flushing cycle is not
necessary, always close the gas cock.
Nozzle is connected to vacuum piping and gas piping.
To prevent the air from the counter current during the
vacuuming operation, the ball cock is installed to the
gas piping.
When the gas flushing function in not used, please close
the ball cock before starting the operation.
Open
Close
NT series
NTW series
LOS-NT/NTW series Operating Instructions Ver.6.02E
21
7-14 Connecting the gas cylinder and
gas adjuster
7-13 Ball cock for gas piping
Attention
At the factory shipment, this ball cock is set
open. When choosing vacuum and seal
(without gas flushing) operation, always turn
the cock 90° to close the gas piping. If the
cock is not closed firmly, the air may return
from the gas nozzle.
Gas cock
Gas cock
Содержание LOS NT Series
Страница 43: ...LOS NT NTW series Operating Instructions Ver 6 02E 43...
Страница 52: ...LOS NT NTW series Operating Instructions Ver 6 02E 52 16 Piping diagram 16 1 LOS NT series piping diagram...
Страница 53: ...LOS NT NTW series Operating Instructions Ver 6 02E 53 16 2 LOS NTW series piping diagram...
Страница 57: ...LOS NT NTW series Operating Instructions Ver 6 02E 57...
Страница 63: ...LOS NT NTW series Operating Instructions Ver 6 02E 63...