VENTILATION PROFILES
USING THE UNIT
4. The first information display for the profile opens. This display
shows the following information:
Ć
Duration
— Indicates the duration of enhanced ventilation
when the
Fireplace profile
is activated. The value is shown in
hours and minutes.
Ć
Supply fan speed
— Indicates the percentage of the supply
air fan speed relative to the maximum speed.
Ć
Extract fan speed
— Indicates the percentage of the extract
air fan speed relative to the maximum speed.
MODIFYING THE PROFILE SETTINGS
IMPORTANT
The system does not automatically save any settings, not even
those that are currently in use. Your settings may be lost during, for
example, a power outage. Remember to save your settings by
selecting Expert settings > Save and restore settings.
MODIFYING THE AT HOME PROFILE SETTINGS
1. Open the main display of the
At home
profile.
2. Press the
Profile information
button.
3. Press the
Edit
button.
4. The fan speed setup opens.
5. Use the
Plus
and
Minus
buttons to set the
At home
profile
fan speed as a percentage of the maximum output ratio.
6. Press the
Right arrow
button.
7. The temperature setup opens.
8. Set the desired supply air temperature for the
At home
profile by using the
Plus
and
Minus
buttons. You can
adjust the temperature in the range +10°C ... +25°C. The
recommended temperature is +15°C or 2—3°C below the
room temperature.
9. Press the
Right arrow
button.
10. The setup for automatic fan speed control based on the
relative humidity opens.
11. Use the
Plus
and
Minus
buttons to select whether the
automatic fan speed control, based on the relative humidity,
is used or not.
12. Press the
Right arrow
button.
13. The setup for automatic fan speed control based on the
carbon dioxide level opens.
14. Use the
Plus
and
Minus
buttons to select whether the
automatic fan speed control, based on the carbon dioxide
level, is used or not.
15. Press the
OK
button.