USING THE UNIT
VENTILATION PROFILES
THE VALLOX VENTILATION UNIT HAS FOUR VENTILATION PROFILES:
AT HOME
Use this ventilation
profile when the
apartment or
the premises is
occupied
AWAY
Use this ventilation
profile when the
apartment or premises
are unoccupied, e.g.
during a trip or other
long absence.
FIREPLACE PROFILE
Use this ventilation profile when, for
example, you are making a fire in
the fireplace. This profile is primarily
used to create momentary
overpressure in the apartment.
VENTILATION
BOOST
Use this profile to increase
the ventilation rate, e.g.
when there are more
people than usual in the
apartment or elsewhere
on the premises.
SYMBOLS FOR VENTILATION PROFILES
The following symbols are used on the main displays of
the profiles: Table 2. Profile symbols
SYMBOL
DESCRIPTION
When this symbol appears on the display, either the At home, Away or Boost profile is in
use. The Week clock is turned off.
When this symbol appears on the display, either the At home, Away or Boost profile is in
use. The Week clock is on.
When this symbol appears on the display, the Fireplace profile is in use. The Week clock
might be turned on.
These symbols indicate the fan speed of the currently active profile. The smallest fan
icon indicates that the Away profile is in use, and the largest fan icon indicates that the
Boost profile is being used.
Droplet symbols indicate the relative humidity of air. The symbols are:
•
One drop: — The humidity sensor has been successfully installed and the relative
humidity of air is normal.
•
Two drops — The relative humidity of air is slightly higher than normal. The fan speed
will be automatically increased if automatic adjustment is allowed.
•
Three drops — The relative humidity of air is significantly higher than normal. The fan
speed will be automatically increased if automatic adjustment is allowed.
These symbols indicate the carbon dioxide level in the air. The colour codes are:
•
Green — The carbon dioxide sensor has been installed and the carbon dioxide
level is normal.
•
Orange — The carbon dioxide level is slightly higher than normal. The fan speed will
be automatically increased if automatic adjustment is allowed.
•
Red — The carbon dioxide level is significantly higher than normal. The fan speed
will be automatically increased if automatic adjustment is allowed.