Page 31
Installation Instructions and Owner’s Manual - L48
ENGLISH
VENT TERMINATION CLEARANCES
Termination clearance for buildings with combustible and non combustible exteriors.
INSIDE CORNER
“A” = COMBUSTIBLE 9” (229mm)
= NONCOMBUSTIBLE 2” (51mm)
OUTSIDE CORNER
“F” = COMBUSTIBLE 6” (152mm)
= NONCOMBUSTIBLE 6” (152mm)
BALCONY
WITH NO SIDE WALL
“I” = COMBUSTIBLE 12” (457mm)
= NONCOMBUSTIBLE 12” (305mm)
ATTENTION:
Vinyl Soffit,
Vinyl Ceiling,
Vinyl Overhang
Disclaimer
Clearances are to heat
resistant material (i.e.
wood, metal). This does
not include vinyl. SBI will
not be held responsible
for heat damage caused
from terminating under
vinyl overhangs, vinyl
ceilings or vinyl ventilated/
unventilated soffits.
BALCONY
WITH PERPENDICULAR SIDE WALL
“G” = COMBUSTIBLE 9” (229mm)
= NONCOMBUSTIBLE 2” (51mm)
“H” = COMBUSTIBLE 18” (457mm)
= NONCOMBUSTIBLE 12” (305mm)
RECESSED LOCATION
“C” = CLEARANCE FROM CORNER
IN RECESSED LOCATION
COMBUSTIBLE 9” (229mm)
NONCOMBUSTIBLE 2” (51mm)
“D” = MINIMUM WIDTH FOR BACK WALL
OF A RECESSED LOCATION
COMBUSTIBLE 38” (965mm)
NONCOMBUSTIBLE 24” (610mm)
“E” = MAXIMUM DEPTH OF 48” (1219mm)
FOR RECESSED LOCATION
Vertical Sidewall Installations
Important!
Minimum clearance between vent pipes and combustible materials is 3 inch (76 mm) on
top, and 1 inch (25 mm) on bottom and sides.
Important!
When vent termination exits through foundation less than 20 inch (508 mm) below siding
outcrop, the vent pipe must extend outward so that the horizontal vent termination is located flush to,
or beyond the outcrop siding.
Information on Various Venting Routes and Components Important:
It is always best to locate
the fireplace in such a way that minimizes the number of offsets and horizontal vent length Since it is
very important that the venting system maintain its balance between the combustion air intake and the
flue gas exhaust, certain limitations as to vent configurations apply and must be strictly adhered to.
The graph showing the relationship between vertical and horizontal side wall venting will help to
determine the various vent lengths allowable. The horizontal vent run refers to the total length of vent
pipe from the flue collar of the fireplace to the face of the outer wall. Venting termination shall not be
recessed into wall or siding