Page 26
Installation Instructions and Owner’s Manual - L48
ENGLISH
VENT SYSTEM IDENDIFICATION
Begin the vent system installation by selecting
the type of venting to be installed and the path it
will take. Verify clearances are met throughout
the path of the venting system.
NOTICE:
Some fireplaces cannot be vented
out the rear of the fireplace.
Determine how the vent system will be
terminated out the side of the house or through
the roof. Verify clearances for the termination.
When selecting a vent system for use with the
fireplace, refer to the “Special Vent Systems”
section in this manual to determine what
systems are acceptable. Check all clearances
and venting components. Identify if any
problems exist in the vent system. Check pipe
diameter on vent system and fireplace to verify
the size is the same.
FLASHING
STORM
COLLAR
VERTICAL
TERMINATION
(THREE 90°
ELBOWS MAX)
WALL
THIMBLE
HORIZONTAL
TERMINATION
(THREE 90°
ELBOWS MAX)
90° ELBOW
OR
45° ELBOW
90° ELBOW
CEILING
FIRE STOP
WALL STRAP
PIPE LENGTH
THIMBLE
SPACER
Figure 33
NOTICE: All outer connection joints must
be sealed with aluminum tape, screws or
silicone sealant rated above 300°F/149°C.
The inner flue joints do not require any
sealant.
The following vent systems are acceptable for
use with the L48 fireplace:
• Simpson Duravent® GS 5in - 8in
• American Metal Products 5in - 8in
• Selkirk Direct-Temp® 5in - 8in
• Security Secure Vent® 5in - 8in
• Excel DV Venting 5in - 8in
• Olympia Ventis 5in - 8in
• BDM - 5in - 8in
• Metal Fab 5in - 8in
WARNING
Gas appliance must not be connected
to a chimney flue serving a separate
solid-fuel burning appliance.