CLERANCES
The minimum clearance from bottom of the
fireplace to ceiling is 65-in. The minimum
clearance from side of the fireplace opening to
adjacent sidewall is 8-in.
8” MIN.
(20cm)
TO
BOTT
OM
OF CABINET
CEILING
TO
BOTT
OM OF
VENTED OPENING
57
5/8”
MIN
(146cm)
65”
MIN
(165cm)
Figure 2
Clearances to Combustibles
Back
See
Side
3"
Floor
0"
Top Stand-off Bracket
0"
Top Framing Edge
13"
SEE MANTEL CHART FOR
MAXIMUM MANTEL DEPTH
13” MIN.
2” X 4” HEADER
STAND-OFF
13” (76mm) HEIGHT
ABOVE TOP OF FIREPLACE
FINISHED WALL
(COMBUSTIBLE)
NON-COMBUSTIBLE
BOARD
TOP FRAMING LEDGE
SEE MANTEL CHART
FOR MINIMUM HEIGHT
OF MANTEL ABOVE
UNIT OPENING
BARRIER
SCREEN/GLASS
FRONT
Figure 3
NOTE :
See
for maximum mantel
depth and minimum height above fireplace.
8”
3”
3”
2”
NOTE: COMBUSTIBLE MATERIALS ALLOWED IN SHADED AREA
3”
Figure 4
Mantel Chart
TOP EDGE OF
FIREPLACE OPENING
H
22”
34”
12”
A
3”
MINIMUM
NON-COMBUSTIBLE MA
TERIAL
ZONE
Figure 5
Index
letter
Distance from
fireplace opening
Distance
from finished
wall
A
34"
12"
B
34"
10"
C
32"
8-3/8"
D
30"
6-5/8"
E
28"
5"
F
26"
3-3/8"
G
24"
1-3/4"
H
22"
0"