background image

Page 63

Installation and Operation Manual - FP10 Lafayette II

ENGLISH

Installation

It is strongly recommended to wear gloves to complete the installation.

A)  Remove the knockouts that close the 8" (20 cm) diameter holes on top of the fireplace. Then cut 

and remove the insulation and the other set of knockouts inside the fireplace.

B)  Secure the 2 anchor plates 

(E)

 with 8 screws provided 

(F)

 on top of the fireplace (4 for each 

anchor plate). Insert the telescoping section 

(D)

 into each anchor plate and secure it with 6 other 

self-tapping screws provided 

(G)

.

1

2

F

D

8X

1

G

6X

2

E

Содержание FP10R

Страница 1: ...URE TO FOLLOW THESE INSTRUCTIONS COULD RESULT IN PROPERTY DAMAGE BODILY INJURY OR EVEN DEATH READ AND KEEP THIS MANUAL FOR REFERENCE 46103A 2022 08 17 FP10 LAFAYETTE II FP10R model Safety tested accor...

Страница 2: ......

Страница 3: ...fireplace and the chimney that it is connected to It is also highly recommended to inform your home insurance company Please read this entire manual before installing and using this fireplace A primar...

Страница 4: ...ating the Fireplace 18 4 1 Using a Fire Screen 18 4 2 Blower Operation 18 5 Burning Wood Efficiently 19 5 1 First Use 19 5 2 Lighting Fires 19 5 3 Combustion Cycles 21 5 4 Rekindling a Fire 22 5 5 Rem...

Страница 5: ...Overlay Installation 51 Appendix 2 Faceplate and Louvers Installation 52 Appendix 3 Optional Fresh Air Intake Installation 53 Appendix 4 Optional Traditional Gravity Hot Air Distribution Kit Installat...

Страница 6: ...Page 6 Installation and Operation Manual FP10 Lafayette II ENGLISH CERTIFICATION PLATE...

Страница 7: ...l firewood This wood heater needs periodic inspection and repairs for the proper operation It is against federal regulations to operate this wood heater in a manner inconsistent with operating instruc...

Страница 8: ...manufacturer as its capacity to maintain a minimum acceptable temperature in the designated area in case of a power failure 2 The overall firebox calculation is an approximation and is not intended to...

Страница 9: ...ULC S610 12 North south ends of the logs visible East west sides of the logs visible 13 Mobile homes Canada or manufactured homes USA The US Department of Housing and Urban Development describes manuf...

Страница 10: ...H 2 3 Dimensions 18 3 8 467mm O 6 150mm 8 1 8 206mm 13 3 8 341mm 9 1 8 231mm G G 28 5 8 727mm Figure 1 Top view 24 3 8 619mm 12 5 8 321mm 10 1 2 268mm 25 3 8 645mm Figure 2 Front view Figure 3 Front v...

Страница 11: ...ctrical inlet F 40 5 8 1032mm 15 3 4 401mm 16 5 8 422mm 37 1 4 945mm 28 3 8 722mm 2 1 2 64mm A F 23 7 8 607mm 4 7 8 125mm Figure 4 Left side view Figure 5 Right side view 12 1 4 310mm 4 1 2 116mm A 36...

Страница 12: ...l FP10 Lafayette II ENGLISH 17 1 2 446mm 20 3 8 516mm 18 7 8 479mm 9 229mm Figure 7 Combustion chamber Top view 1 2 13mm MIN 1 25mm MAX 12 1 8 307mm 12 7 8 328mm Figure 8 Left view Faceplate projectio...

Страница 13: ...evel the coal bed and put 5 logs in the firebox Place 2 small pieces about 3 x 3 in the bottom in a reverse V shape then put two medium size pieces about 4 x4 in an East West orientation in the back o...

Страница 14: ...cals It is made of natural raw materials such as sand and quartz that are combined in such a way to form a high temperature glass Ceramic glass cannot be recycled in the same way as normal glass so it...

Страница 15: ...ures of this fireplace can only work properly if the fuel used is in the correct moisture content range of 15 to 20 Refer to the following section of suggestions on preparing fuelwood and judging its...

Страница 16: ...of hardwood 3 2 Log Length Logs should be cut at least 1 25 mm shorter than the firebox so they fit in easily Pieces that are even slightly too long makes loading the fireplace very difficult The mos...

Страница 17: ...mer weather than in winter weather Split pieces dry more quickly than unsplit rounds Softwoods like pine spruce poplar and aspen take less time to dry than hardwoods They can be dry enough to burn aft...

Страница 18: ...nction is to increase airflow around the fireplace air jacket and improve hot air circulation in the room When used regularly the blower can provide a small increase in efficiency up to 2 However the...

Страница 19: ...ay to light fires Regardless of the method chosen the goal should be to have a hot fire burning quickly A fire that ignites fast produces less smoke and deposits less creosote in the chimney 5 2 1 EPA...

Страница 20: ...at right angles and place a dozen finely split kindling on the second row It is possible to use ragged paper but it may not hold in place since it tends to roll while it is burning The best is to wrap...

Страница 21: ...ns best in cycles A cycle starts when a new load of wood is ignited by hot coals and ends when that load has been consumed down to a bed of charcoal about the same size as it was when the wood was loa...

Страница 22: ...is pleasant when the room temperature is cool but can be unpleasant when the room is already warm Therefore it is best to let each load of wood burn completely so that the room cools down before putt...

Страница 23: ...eat output to the desired temperature in the house A house will need far less heating in October than in January to maintain a comfortable temperature Filling the firebox full in fall weather will ove...

Страница 24: ...e of the space to be heated the climate zone where the house is and the time of the year The table below gives an approximate maximum burn cycle times based on firebox volume Table 1 Approximate Maxim...

Страница 25: ...int 6 2 Refractory Material and Baffle The intense heat of the fire can cause slight cracks in the refractory panels It is possible to minimize the appearance of these cracks by hardening the panels a...

Страница 26: ...ce The replacement glass must have a gasket all around 5 Reinstall the glass being careful to centre the glass in the door and not to over tightening the retaining screw The two main causes of broken...

Страница 27: ...the paper slips out easily anywhere either adjust the door or replace the gasket At the end of each heating season it is recommended to add a high temperature graphite paste on the threads of the door...

Страница 28: ...n to adjust the doors Tighten the set screws on the door hinges when they are in the desired positions Doors position with more space Doors position with less space Doors tilt up Doors tilt down Top p...

Страница 29: ...osote vapors condense in the relatively cooler chimney flue of a slow burning fire As a result creosote residue accumulates on the flue lining When ignited this creosote makes an extremely hot fire Th...

Страница 30: ...possible danger 3 If you require assistance alert the fire department 4 If possible use a dry chemical fire extinguisher baking soda or sand to control the fire Do not use water as it may cause a dang...

Страница 31: ...ace must always be used with the original andirons Do not use a fireplace insert and other products not specified for use with this fireplace Do not install in a mobile home Canada or manufactured hom...

Страница 32: ...best location for the fireplace should consider the location of windows doors and circulation in the room There must be enough space in front of the fireplace for the hearth extension and mantel and o...

Страница 33: ...le depth 3 76 mm Mantle minimum distance 8 203 mm measured from the door opening Side wall distance 13 330 mm measured from the door opening Minimum distance to the wall in front of the fireplace 48 1...

Страница 34: ...uld be installed as follows The headers must be 2 x 3 5 cm x 8 cm or 2 x 4 5 cm x 10 cm Do not put wood or other material in the area above the fireplace Install only the cripple studs needed to suppo...

Страница 35: ...ickness must be added to the following measurements A Fresh air intake duct16 Fresh air intake can be installed on the right or underneath B Distance between framing and side fireplace standoff 12 305...

Страница 36: ...4 3 8 365mm Framing configuration should be used as a reference only If a finishing material is installed inside the enclosure its thickness must be added to the following measurements Theses values a...

Страница 37: ...t be protected over the entire width of the floor protection by a folded and continuous metal sheet D min 2 51 mm not supplied A clearance of 80 2 03 m between the base of the fireplace and the ceilin...

Страница 38: ...must be respected 8 6 4 Floor Protection OPTION INSTALLATION TYPE R FACTOR REQUIRED A B C 1 On floor level Yes 1 00 16 406 mm 41 1054 mm 8 203 mm 2 Raised base of 4 or less Yes 1 00 16 406 mm 41 1054...

Страница 39: ...Marble 14 3 20 00 0 07 0 05 Ceramic tile 12 5 0 008 Concrete 1 050 0 950 Mineral wool insulation 0 320 3 120 Limestone 6 5 0 153 Ceramic board Fibremax 0 450 2 2 Horizontal still air 3 mm thick 0 135...

Страница 40: ...6 152 mm C can be installed at least 58 1 47 m B from the base of the fireplace Different shelf sizes are listed in the following table POSITIONING AND DEPTH OF THE THE SHELF B C 58 1 47 m 6 152 mm 60...

Страница 41: ...ly and efficiently as intended if it is not connected to a suitable chimney The heat in the flue gases that pass from the fireplace into the chimney is not waste heat This heat is what the chimney use...

Страница 42: ...ollowing installation instructions To ensure a safe installation please refer to it Some non illustrated parts may be required 9 3 1 General Advices This wood burning fireplace has optimum performance...

Страница 43: ...and can lead to draft problems If the chimney extends higher than 5 ft 1 5 m above its point of contact with the roof it must be secured using a roof brace A rain cap must be installed on top of the c...

Страница 44: ...minations must be separated by at least 16 410 mm horizontally and 18 460 mm vertically This separation is to prevent smoke migrating from one chimney to another CHIMNEY 12 305mm MIN ABOVE FLASHING FL...

Страница 45: ...een the chimney and any combustible materials Do not fill this 2 space with insulation or any other combustible material In all cases the chimney must start with a 6 diameter anchor plate attached to...

Страница 46: ...the chimney will pass In the attic install an attic radiation shield from above D 3 Install an anchor plate A and a first chimney section on the fireplace Install the number of chimney sections neede...

Страница 47: ...owing the instructions of the ceiling supported installation Table 3 Minimum system height when using elbows Chimney model See Table 4 Vertical Installation 15 ft 4 6 m Two 2 elbows 15 ft 4 6 m Four 4...

Страница 48: ...r s instructions to connect the extended liner section to the special chimney connector The liner must extend at least 12 30 cm above the masonry chimney 9 4 Angled Wall Pass Thru Installation When pa...

Страница 49: ...ympia Chimney Champion Chimney System 1 Solid Pack 6 15 cm Olympia Chimney Rockford Chimney Systems 1 Solid Pack 6 15 cm Selkirk CF Sentinel CF 2 Solid Pack 6 15 cm Selkirk Super Pro 2100 ALT 2 Solid...

Страница 50: ...eld unless chimney is enclosed at the attic level 2 Solid Pack S 2100 DuraVent Ventilated roof flashing 1 Solid Pack Dura Tech Dura Tech Canada DTC 2 Solid Pack Dura Tech Premium American Metal Chimne...

Страница 51: ...1 DOOR OVERLAY INSTALLATION Position the overlay R on the door frame and secure using the bolts S To facilitate the installation do not tighten the nuts until they are all installed Note It is not nec...

Страница 52: ...ALLATION A faceplate must be installed on this fireplace Five choices of louvers are offered See the faceplate installation manual for more details Figure 10 Classic style louvers Figure 11 Arabesque...

Страница 53: ...installed above or below the floor level The air intake should be installed high enough not to be obstructed by snow It should be protected from the wind away from automobile exhaust a gas meter or ot...

Страница 54: ...nstall the adapter included in the fireplace 2 and align the notch of the adapter T with the one on the fireplace Turn the adapter clockwise T 1 2 Figure 15 Fresh air intake on the right side Figure 1...

Страница 55: ...t Secure the plastic with aluminum tape 5 To complete the installation make a hole of to 6 mm to 13 mm bigger than the duct diameter on the outside wall of the house at the chosen location From outsid...

Страница 56: ...o elbows C 6 steel brackets D with fastening screws E and self tapping screws F Parts not included in the kit 8 rigid ducting G 26 ga galvanized steel Dimensions of hot air outlet frame with elbow Dim...

Страница 57: ...air outlets can be installed in the same room as the fireplace or both can be installed in adjacent rooms or upstairs If the outputs are installed at different heights the higher output will draw more...

Страница 58: ...that close the 8 20 cm diameter holes on top of the fireplace Then cut and remove the insulation and the other set of knockouts inside the fireplace B Screw the 6 steel brackets D with 6 screws E onto...

Страница 59: ...self drilling screws 3 per elbow Insert the frames B into the elbow outlets C Press the frame on the back of the non combustible wall and screw it in place Screw the frame B to the outlet of the elbo...

Страница 60: ...me B Heat distribution box C Telescoping section D Anchor plates E All screws are included Not included in the kit 8 rigid ducting 26 ga galvanized steel if necessary according to the desired height D...

Страница 61: ...rative plate Dimensions of assembled heat distribution box and adjustable decorative plate Dimensions of telescoping section 5 3 8 138mm 7 1 8 181mm 32 814mm 34 1 8 867mm 2 52mm 3 76mm 0 0mm MIN 12 1...

Страница 62: ...stairs When forced air kit is installed in conjunction with a gravity kit the forced air device will draw some of the air from the gravity kit ducting therefore reducing its efficiency Clearances Ther...

Страница 63: ...ose the 8 20 cm diameter holes on top of the fireplace Then cut and remove the insulation and the other set of knockouts inside the fireplace B Secure the 2 anchor plates E with 8 screws provided F on...

Страница 64: ...telescoping section Determine the needed height and secure the two parts of the telescoping sections together with 3 self tapping screws Insert the adjustable frame B in the heat distribution box C p...

Страница 65: ...andard states that it is necessary to perform certification testing with any ventilation that is likely to alter the units performance For this reason SBI has tested the effects of the forced air kit...

Страница 66: ...or more details refer to the installation manual supplied with the fire screen Warning Never leave the fireplace unattended while in use with the firescreen 1 Open the door 2 Hold the firescreen and b...

Страница 67: ...S REPLACEMENT 1 Using a ratchet and a Torx T 30 bit unscrew the two screws V holding the andiron U 2 Remove the floor refractory panel W T 30 U V W 3 Using a power driver remove the refractory panels...

Страница 68: ...the rear left channel 2 Align the notch in the left end of the tube with the key of the left air channel hole Using a Wise grip hold the tube and lock it in place by turning the tube as shown Make sur...

Страница 69: ...e blower replacement it is recommended to remove the faceplate first Refer to the faceplate installation manual for more details 1 Remove the air control decorative panel J by removing the screws K 2...

Страница 70: ...n Connect the wires from the power outlet to the terminal block making sure that the white wire matches the white wire on the terminal Connect the black wire with the black wire of the terminal block...

Страница 71: ...RAM AND PARTS LIST C DETAIL C B DETAIL B D DETAIL D E DETAIL E F DETAIL F 31 32 33 35 36 34 66 70 37 38 39 40 41 43 42 44 45 46 48 47 51 50 52 65 64 56 55 61 62 60 58 59 57 3 1 63 23 24 22 16 18 17 19...

Страница 72: ...ET 1 12 PL72300 DOOR HANDLE STOPPER 1 13 30355 MECHANICAL SCREW 10 24 x PAN SQUARE ZINC 3 14 SE72301 FP10R FIREPLACE REPLACEMENT GLASS 1 15 AC06400 3 4 FLAT X 6 BLACK SELF ADHESIVE GLASS GASKET 1 16 P...

Страница 73: ...6 HINGE PIN 2 54 30117 SOCKET SET SCREW 10 32 X 1 4 2 55 60204B TERMINAL BLOCK END SECTION 1 56 60204A TERMINAL 3 8 SECTION 2 57 44028 CERAMIC THERMODISC F110 20F 1 58 44084 RHEOSTAT WITHOUT NUT AND F...

Страница 74: ...ed rate schedule and must not exceed the wholesale price of the replacement part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its di...

Страница 75: ......

Страница 76: ...NOTES...

Страница 77: ...NOTES...

Страница 78: ...tional com This document is available for free download on the manufacturer s website It is a copyrighted document Resale is strictly prohibited The manufacturer may update this document from time to...

Отзывы: