2.4 EPA Certification Loading
The loading methods shown below are those used during emissions certification.
2.4.1 Air control
The air control is located below the ash shelf on the
right. To open the air control, push the air control handle
completely to the left (High). This will increase the burn
rate. To close the air control, push the air control handle
completely to the right (Low). This will decrease the
burn rate.
2.4.2 High burn rate (primary air control open)
Open the air control completely. Criss cross 10 small
pieces (2”x2”) of wood into the firebox in 3 layers (2 at
the bottom, 4 in the middle and 4 on top). Criss cross
10 to 12 finely split kindling wood pieces over the small
pieces of wood. Tie knot with five sheets of paper and
place them on top of the kindling wood. Light up the paper and let the door completely open
until the 2 top layers are burning. Close the door. When the kindling and the small pieces of
wood are almost completely burnt out and it is possible to break them into small pieces, level
the coal bed and put 5 logs in the firebox. Place 2 small pieces (about 3” x 3”) in the bottom in
a reverse V shape, then put two medium size pieces (about 4”x4”) in an East-West orientation
in the back (over the reverse V). Put a big piece (about 5”x5”) in the front over the reverse V. Try
to leave air space between the pieces. Let the door fully open for 3 minutes or when the fire is
fully established and close the door. Leave the air control fully opened.
2.4.3 Medium and low burn rate
On a 2” coal bed that is dark red, add 6 pieces of wood in the firebox. Place 2 small pieces
(about 2.5” x 2.5”) in the bottom in a reverse V shape, then put 2 medium size pieces (about
4”x4”) in an East-West orientation in the back (over the reverse V). Put a big piece (about 5”x5”)
in an East-West orientation in the front (over the reverse V) and put a last medium size piece
(about 4”x4”) over the two medium size pieces in the back. Try to leave air space between the
pieces. Let the door open at 90° for 3 minutes 30 seconds or when the fire is fully established
and close the door. Leave the primary air control open for approximately 5 minutes and then
close the primary air control halfway. After another 5 minutes, close the air control completely
for the low burn rate and 3/8” open for the medium burn rate.