6.4 Door
In order for the fireplace to burn at its best efficiency, the door
must provide a perfect seal with the firebox. Therefore, the gasket
should be inspected periodically to check for a good seal. The
tightness of the door seal can be verified by closing and latching
the door on a strip of paper. The test must be performed all around
the door. If the paper slips out easily anywhere, either adjust the
door or replace the gasket.
At the end of each heating season it is recommended to add a high temperature graphite paste
on the threads of the door handle. This paste wil protect the threads from rust and prevent dust
accumulation that can prevent the handle from rotating freely.
6.4.1 Adjustment
The gasket seal may be improved with a simple latch mechanism adjustment:
1. Remove the screws
(B)
and the door latch stopper
(A)
.
2. Turn the handle counter-clockwise to increase pressure between the door and the fireplace.
3. Reinstall the screws and the door latch stopper.