Page 45
Installation and Operation Manual - FP10 Lafayette II
ENGLISH
• Cut and frame square holes in all floors, ceilings, and roof that the chimney will go through to
provide a 2" (50 mm) minimum clearance between the chimney and any combustible materials.
Do not fill this 2" space with insulation or any other combustible material.
• In all cases, the chimney must start with a 6" diameter anchor plate attached to the fireplace.
• If the male anchor plate nozzle exceeds 2" (50 mm) in length
(A)
, it must be cut above the
lifting hooks welded inside the flue outlet so that it is sitting perfectly on the top of the
fireplace.