Page 55
Installation and Operation Manual - FP10 Lafayette II
ENGLISH
4. Install the flexible duct
(D)
on the fresh air inlet adapter
(B)
using one hose clamp
(C)
. Fix the
other end to the outer wall register
(E)
using the second hose clamp
(C)
. The outer wall register
(E)
must be installed outside the house.
To properly install the flexible duct, gently remove the insulation and plastic wrap to expose
the duct. Fix the duct using clamps. Stick aluminum tape around the joint between the duct
and adapter to make the connection airtight. Carefully replace the insulation and plastic wrap
on the duct. Secure the plastic with aluminum tape.
5. To complete the installation, make a hole of ¼" to ½" (6 mm to 13 mm) bigger than the duct
diameter on the outside wall of the house at the chosen location. From outside, place the outside
wall register in the hole (open side down) and fasten the register to the wall, with screws.
Use the required length for the installation while respecting the maximum length of 30'
(9 m). To avoid condensation, it is recommended to use an insulated duct long enough and
containing a «P-Trap» loop. This configuration can be done inside the chase, but must at all
times maintain clearances to combustibles.
It is strongly recommended to install a mechanical shutter that closes the outside air inlet
when the fireplace is not in use.
B
C
D
C
E
B
C
D
C
E
G
F
MIN 10 pi
MAX 3 pi
Содержание FP10R
Страница 2: ......
Страница 6: ...Page 6 Installation and Operation Manual FP10 Lafayette II ENGLISH CERTIFICATION PLATE...
Страница 75: ......
Страница 76: ...NOTES...
Страница 77: ...NOTES...