8.5
Solenoid valve test errors (501 to 514)
No. 501
SOT start condition: Not at operational
Description
The valve is not at the operational position
Trouble shooting
This error can be solved by
•
Make sure the valve is at the operational position
•
Perform an endpoint calibration.
•
Increase the solenoid test position deadband
No. 502
SOT start condition: Low start pressure
Description
The measured pressure is below Start pressure low
Trouble shooting
This error can be solved by:
•
Increase the pressure in the system
•
Decrease the Start pressure low
No. 503
SOT start condition: High start pressure
Description
The measured pressure is above Start pressure high
Trouble shooting
This error can be solved by:
•
Decrease the pressure in the system
•
Increase Start pressure high
No. 504
SOT start condition: In ESD mode
Description
Emergency shutdown is detected
Trouble shooting
This error can be solved by:
•
Activate the ESD input
No. 506
Aborted by the user
Description
The test was aborted by the user
Trouble shooting
This error can be solved by:
•
Perform a new SOT